B-66 T60 Transformer Protection System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
C5FC ...Repeated for Contact Output 38
C608 ...Repeated for Contact Output 39
C614 ...Repeated for Contact Output 40
C620 ...Repeated for Contact Output 41
C62C ...Repeated for Contact Output 42
C638 ...Repeated for Contact Output 43
C644 ...Repeated for Contact Output 44
C650 ...Repeated for Contact Output 45
C65C ...Repeated for Contact Output 46
C668 ...Repeated for Contact Output 47
C674 ...Repeated for Contact Output 48
C680 ...Repeated for Contact Output 49
C68C ...Repeated for Contact Output 50
C698 ...Repeated for Contact Output 51
C6A4 ...Repeated for Contact Output 52
C6B0 ...Repeated for Contact Output 53
C6BC ...Repeated for Contact Output 54
C6C8 ...Repeated for Contact Output 55
C6D4 ...Repeated for Contact Output 56
C6E0 ...Repeated for Contact Output 57
C6EC ...Repeated for Contact Output 58
C6F8 ...Repeated for Contact Output 59
C704 ...Repeated for Contact Output 60
C710 ...Repeated for Contact Output 61
C71C ...Repeated for Contact Output 62
C728 ...Repeated for Contact Output 63
C734 ...Repeated for Contact Output 64
Reset (Read/Write Setting)
C750 FlexLogic™ operand which initiates a reset 0 to 65535 --- 1 F300 0
Control Pushbuttons (Read/Write Setting) (7 modules)
C760 Control Pushbutton 1 Function 0 to 1 --- 1 F102 0 (Disabled)
C761 Control Pushbutton 1 Events 0 to 1 --- 1 F102 0 (Disabled)
C762 ...Repeated for Control Pushbutton 2
C764 ...Repeated for Control Pushbutton 3
C766 ...Repeated for Control Pushbutton 4
C768 ...Repeated for Control Pushbutton 5
C76A ...Repeated for Control Pushbutton 6
C76C ...Repeated for Control Pushbutton 7
Clear Records (Read/Write Setting)
C771 Clear User Fault Reports Operand 0 to 65535 --- 1 F300 0
C772 Clear Event Records Operand 0 to 65535 --- 1 F300 0
C773 Clear Oscillography Operand 0 to 65535 --- 1 F300 0
C774 Clear Data Logger Operand 0 to 65535 --- 1 F300 0
C775 Clear Breaker 1 Arcing Current Operand 0 to 65535 --- 1 F300 0
C776 Clear Breaker 2 Arcing Current Operand 0 to 65535 --- 1 F300 0
C777 Clear Breaker 3 Arcing Current Operand 0 to 65535 --- 1 F300 0
C778 Clear Breaker 4 Arcing Current Operand 0 to 65535 --- 1 F300 0
C77B Clear Demand Operand 0 to 65535 --- 1 F300 0
C77D Clear Energy Operand 0 to 65535 --- 1 F300 0
C77F Clear Unauthorized Access Operand 0 to 65535 --- 1 F300 0
C781 Clear Platform Direct Input/Output Statistics Operand 0 to 65535 --- 1 F300 0
C783 Reserved (13 items) --- --- --- F001 0
Force Contact Inputs/Outputs (Read/Write Settings)
C7A0 Force Contact Input x State (96 items) 0 to 2 --- 1 F144 0 (Disabled)
Table B–10: MODBUS MEMORY MAP (Sheet 58 of 65)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT