B-68 T60 Transformer Protection System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
CA1E ...Repeated for Direct Output 8
CA20 ...Repeated for Direct Output 9
CA22 ...Repeated for Direct Output 10
CA24 ...Repeated for Direct Output 11
CA26 ...Repeated for Direct Output 12
CA28 ...Repeated for Direct Output 13
CA2A ...Repeated for Direct Output 14
CA2C ...Repeated for Direct Output 15
CA2E ...Repeated for Direct Output 16
CA30 ...Repeated for Direct Output 17
CA32 ...Repeated for Direct Output 18
CA34 ...Repeated for Direct Output 19
CA36 ...Repeated for Direct Output 20
CA38 ...Repeated for Direct Output 21
CA3A ...Repeated for Direct Output 22
CA3C ...Repeated for Direct Output 23
CA3E ...Repeated for Direct Output 24
CA40 ...Repeated for Direct Output 25
CA42 ...Repeated for Direct Output 26
CA44 ...Repeated for Direct Output 27
CA46 ...Repeated for Direct Output 28
CA48 ...Repeated for Direct Output 29
CA4A ...Repeated for Direct Output 30
CA4C ...Repeated for Direct Output 31
CA4E ...Repeated for Direct Output 32
Direct Input/Output Alarms (Read/Write Setting)
CAD0 Direct Input/Output Channel 1 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)
CAD1 Direct Input/Output Channel 1 CRC Alarm Message
Count
100 to 10000 --- 1 F001 600
CAD2 Direct Input/Output Channel 1 CRC Alarm Threshold 1 to 1000 --- 1 F001 10
CAD3 Direct Input/Output Channel 1 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)
CAD4 Reserved (4 items) 1 to 1000 --- 1 F001 10
CAD8 Direct Input/Output Channel 2 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)
CAD9 Direct Input/Output Channel 2 CRC Alarm Message
Count
100 to 10000 --- 1 F001 600
CADA Direct Input/Output Channel 2 CRC Alarm Threshold 1 to 1000 --- 1 F001 10
CADB Direct Input/Output Channel 2 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)
CADC Reserved (4 items) 1 to 1000 --- 1 F001 10
CAE0 Direct Input/Output Channel 1 Unreturned Messages
Alarm Function
0 to 1 --- 1 F102 0 (Disabled)
CAE1 Direct Input/Output Channel 1 Unreturned Messages
Alarm Msg Count
100 to 10000 --- 1 F001 600
CAE2 Direct Input/Output Channel 1 Unreturned Messages
Alarm Threshold
1 to 1000 --- 1 F001 10
CAE3 Direct Input/Output Channel 1 Unreturned Messages
Alarm Events
0 to 1 --- 1 F102 0 (Disabled)
CAE4 Reserved (4 items) 1 to 1000 --- 1 F001 10
CAE8 Direct Input/Output Channel 2 Unreturned Messages
Alarm Function
0 to 1 --- 1 F102 0 (Disabled)
CAE9 Direct Input/Output Channel 2 Unreturned Messages
Alarm Msg Count
100 to 10000 --- 1 F001 600
CAEA Direct Input/Output Channel 2 Unreturned Messages
Alarm Threshold
1 to 1000 --- 1 F001 10
CAEB Direct Input/Output Channel 2 Unreturned Messages
Alarm Events
0 to 1 --- 1 F102 0 (Disabled)
CAEC Reserved (4 items) 1 to 1000 --- 1 F001 10
Remote Devices (Read/Write Setting) (16 modules)
CB00 Remote Device 1 GSSE/GOOSE Application ID (GOID) --- --- --- F209 “Remote Device 1“
Table B–10: MODBUS MEMORY MAP (Sheet 60 of 65)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT