EasyManua.ls Logo

GE UR T60 - 8.3 EnerVista Security Management System

GE UR T60
724 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
viii T60 Transformer Protection System GE Multilin
TABLE OF CONTENTS
10.3 STORAGE
10.3.1 STORAGE ........................................................................................................10-3
10.4 DISPOSAL
10.4.1 DISPOSAL........................................................................................................10-4
A. FLEXANALOG AND
FLEXINTEGER
PARAMETERS
A.1 PARAMETER LISTS
A.1.1 FLEXANALOG ITEMS....................................................................................... A-1
A.1.2 FLEXINTEGER ITEMS.................................................................................... A-24
B. MODBUS
COMMUNICATIONS
B.1 MODBUS RTU PROTOCOL
B.1.1 INTRODUCTION ............................................................................................... B-1
B.1.2 PHYSICAL LAYER ............................................................................................ B-1
B.1.3 DATA LINK LAYER ........................................................................................... B-1
B.1.4 MODBUS RTU CRC-16 ALGORITHM .............................................................. B-2
B.2 MODBUS FUNCTION CODES
B.2.1 SUPPORTED FUNCTION CODES ................................................................... B-4
B.2.2 READ ACTUAL VALUES OR SETTINGS (FUNCTION CODE 03/04H) ........... B-4
B.2.3 EXECUTE OPERATION (FUNCTION CODE 05H)........................................... B-5
B.2.4 STORE SINGLE SETTING (FUNCTION CODE 06H)....................................... B-5
B.2.5 STORE MULTIPLE SETTINGS (FUNCTION CODE 10H)................................ B-6
B.2.6 EXCEPTION RESPONSES............................................................................... B-6
B.3 FILE TRANSFERS
B.3.1 OBTAINING RELAY FILES VIA MODBUS........................................................ B-7
B.4 MEMORY MAPPING
B.4.1 MODBUS MEMORY MAP ................................................................................. B-9
B.4.2 DATA FORMATS............................................................................................. B-74
C. IEC 61850
COMMUNICATIONS
C.1 OVERVIEW
C.1.1 INTRODUCTION ...............................................................................................C-1
C.1.2 COMMUNICATION PROFILES.........................................................................C-1
C.1.3 FILE TRANSFER BY IEC 61850 .......................................................................C-2
C.2 SERVER DATA ORGANIZATION
C.2.1 OVERVIEW .......................................................................................................C-3
C.2.2 GGIO1: DIGITAL STATUS VALUES .................................................................C-3
C.2.3 GGIO2: DIGITAL CONTROL VALUES..............................................................C-3
C.2.4 GGIO3: DIGITAL STATUS AND ANALOG VALUES FROM RECEIVED GOOSE
DATAC-3
C.2.5 GGIO4: GENERIC ANALOG MEASURED VALUES.........................................C-3
C.2.6 MMXU: ANALOG MEASURED VALUES ..........................................................C-4
C.2.7 PROTECTION AND OTHER LOGICAL NODES...............................................C-4
C.3 SERVER FEATURES AND CONFIGURATION
C.3.1 BUFFERED/UNBUFFERED REPORTING........................................................C-6
C.3.2 FILE TRANSFER...............................................................................................C-6
C.3.3 TIMESTAMPS AND SCANNING.......................................................................C-6
C.3.4 LOGICAL DEVICE NAME .................................................................................C-6
C.3.5 LOCATION ........................................................................................................ C-6
C.3.6 LOGICAL NODE NAME PREFIXES..................................................................C-7
C.3.7 CONNECTION TIMING .....................................................................................C-7
C.3.8 NON-IEC 61850 DATA......................................................................................C-7
C.3.9 COMMUNICATION SOFTWARE UTILITIES.....................................................C-7
C.4 GENERIC SUBSTATION EVENT SERVICES: GSSE AND GOOSE
C.4.1 OVERVIEW .......................................................................................................C-8
C.4.2 GSSE CONFIGURATION..................................................................................C-8
C.4.3 FIXED GOOSE ..................................................................................................C-8
C.4.4 CONFIGURABLE GOOSE ................................................................................C-8

Table of Contents

Related product manuals