Component Testing Information
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless
testing requires it.
Illustration Component Test Procedure Results
L1
L2
2
1
Temperature switch Disconnect wires from component to
properly measure the resistance of the
component.
Place switch in the following positions
and measure across the terminals
below:
Hot / Cold L1-2

Warm / Warm L1-1, L1-2, L2-2
L2-1, L2-L1, 1-2

Warm / Cold L1-1, L1-2, 1-2

Cold / Cold L1-1

>1
>1
>1
>1
Mixing valve Measure resistance of terminals on
each valve.
Resistance across each valve.
Approximately 1000
±
10%
Timer Verify input and output voltage is
present.
Verify wiring is correctly connected to
the timer.
See timing sequence chart for functional
description of the component.
1
2
3
Pressure switch
Do not disconnect the pressure hose
from pressure switch to perform
measurements.
Measure resistance across the
following terminals on the pressure
switch:
Terminal 1 to 2
Terminal 1 to 3
Refer to wiring diagram/schematic for
correct contacts.
Air pressure that actuates switch is
determined by the water level of the
tub.
Continuity (no pressure)
Continuity (pressure)
Lid switch
SPST
Disconnect wire terminals from switch.
Test terminals with switch closed.
Test terminals with switch open.
Continuity >1
Infinite 1 M
Brake pad kit If washtub does not stop spinning
within seven seconds after opening
loading door.
If brake pads make noises.
Replace all three brake pads.
Apply a thin layer of silicone lubricant on
pads.