33
in.xe™
Parameter Display Options Description
Output 2 current 1 to 15 amperes Current draw of the accessory connected to the relay of Output 2A
Output 3 current 1 to 15 amperes Current draw of the accessory connected to the relay of Output 3A
Output 4 current 1 to 15 amperes Current draw of the accessory connected to the relay of Output 4A
Output 5 current 1 to 17 amperes Current draw of the accessory connected to the relay of Output 5A
Direct current 0 to 5 amperes Current draw of the Direct output
Minimum input
current
10 to 20 Minimum input current (breaker size)
Number of phases 1 or 2 (UL)
1, 2 or 3 (CE)
Number of Phase / Breaker
Input current 10 to 60A Single Phase (UL and CE)
10 to 48A Dual Phase (UL)
10 to 40A Dual Phase (CE)
10 to 20A Triple Phase (CE)
Available household current
--
--
--
--
--
--
--
--
programming the in.xe™
Number of Phases selection
UL Menu not available
CE 1 or 2
UL Swim 1 or 2
CE Swim 1, 2 or 3
Maximum Input Current
1 phase 2 Phases 3 Phases
UL 48 na na
CE 40 20 na
UL Swim 60 48 na
CE Swim 60 40 na
Table 2