. Installation and Connections
General setup in spa
Install the chamber on a dedicated
bypass and connect the outlet directly
to the spa tub
• The chamber must be installed after
the filter
• The chamber must be installed before
any water treatment device (UV,
Ozonator, etc.)
• Piping and hardware are at
the discretion of the installer.
Our recommendations :
• Use /-inch, /-inch, or /-inch
tubing for the deviation line to the
chamber
• Use PVC piping solvent glue to install
parts on reading chamber valves
• The minimum recommended flow in the chamber is . GPM.
Main
Spa tub
Chamber installation position and orientation
The chamber must be accessible for valve
manipulations, draining, probe installation,
and pressure gauge reading.
The chamber should be oriented so that the probe
and valves are at a vertical angle of +/-°
in any direction.
This ensures correct probe functioning and allows
air to flow out of the chamber
• The probe must be kept in temperature above °C (°F).
• The probe must avoid long air exposure (over min).
• Prior to any installation procedures, turn off the power of the spa
Important notice