15
FLO error message
The system has detected no water flow during the main pumps operation.
• Ensure the water
circulation valves are
open and that the water
level is high enough�
• Verify that nothing is
blocking the filter�
• Ensure the flow is
adequate (minimum
68 LPM/ 18 GPM)�
• Ensure no air bubbles
are trapped in the
plumbing circuits of the
device (the pumps may
be making abnormal
sounds)� If bubbles
have formed, start the
pump, unscrew slowly
one of the union nuts to
free the air trapped in
the plumbing� Tighten
back the nut once done�
• Ensure the pump linked
to the water heater
(main pump) is running�
Ensure that the selected low-level is compatible with your spa’s material� Verify that the pump linked to the heating is
configured correctly� (See HP option in the dealer menu option� For more details on the HP option, refer to the manual
Start up guide and basic configuration for Y series and in�xe)�
Troubleshooting
• For in�yj control systems,
verify the water heater’s
low voltage cable is
linked correctly to the
probe connector (P1)�
in.yj
Probe connector
(heat�wav low voltage cable)
in�flo cable in�flo cable
in.ye and in.yt in.xe
• For the in�ye, in�yt and in�xe control systems, ensure the in�flo cable (located over the
water heater) is plugged in correctly�
• If the problem persists, replace the water heater�
• If the problem still persists, replace the control system
in.ye-V3
in�flo cable