23
If the circulation pump is not working:
The circulation pump is not working
If the circulation pump is
not working :
• Ensure the selected
low-level configuration
is compatible with your
spas material�
• Start the circulation
pump, by setting the
consigned temperature
2 °F above the actual
water temperature�
If the mesured tension is
not compliant:
• Replace the accessories
fuse�
• If replacing the fuse
does not fix the
problem, replace the
control system�
If the measured tension
is compliant:
• Replace the circulation
pump�
Measure the tension
on the corresponding
connector:
• Referring to your control
systems connection
diagram, measure the
tension between: the
output of your circu-
lation pump and its
return�
You should measure:
120V for a 120V
circulation pump
240V for a 240 V
circulation pump
If the ozonator is not working:
The ozonator is not working
Note: The ozonator stops automatically when an accessory is started manually (pumps, blower, light)�
If the ozonator is
not working:
• Verifiy the status of the
filtration cycle indicator
on the keypad display�
• If the «Filtration»
indicator flashs, it is to
signal that the system
has interrupted the
filtration cycle� In that
case, restart the breaker
by cutting off then
restarting the power to
reinitialise the cycle�
If the mesured tension is
not compliant:
• Replace the accessories
fuse�
• If replacing the fuse
does not fix the
problem, replace the
control system�
If the measured tension
is compliant:
• Replace the ozonator�
If the ozonator is not
working and the filtration
indicator is ON:
• Referring to the connec-
tion diagram of your
control system, measure
the tension between:
the ozonator output and
its return�
You should measure:
120V for a 120V
ozonator
240V for a 240V
ozonator
• If not, start the filtration
cycle (see your keypads
techbook for more
information)�
Troubleshooting