80224_MHW_650 L - 1250 L_07-2018_ENG - 64
4. CONFIGURATION
4.12.8. BACKL - Backlighting level
Acronym Scrolling message Submenu Attributes
BACKL BACKLIGHT LEVEL HMI R W
The parameter shows and sets the backlight level on the display (when the indicator is on) 10 seconds after the last key
has been pressed.
With “0,” the backlight does not switch off, but goes to the minimum useful level for reading the display.
The backlight goes to maximum level when any key is pressed.
Unit of measurement: -
Options: 0...10 (default = 8)
4.12.9. QUICK - Quick configuration menu
Acronym Scrolling message Submenu Attributes
QUICK QUICK CONFIG ENABLE HMI R W
The parameter shows and sets enabling of the quick configuration menu.
Unit of measurement: -
Options: OFF = Quick configuration menu is not displayed
On = Quick configuration menu is displayed