EasyManuals Logo

gefran ADL500 User Manual

gefran ADL500
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
68 ADL500 • Quick installation guide - Specifications and connection
Step 5 – Setting the maximum speed reference and maximum system speed
Select the unit of measurement for the speed references
STARTUP WIZARD
Set speeds?
E=Yes Down=Next
E
01 /08
PAR: 11020
Multi speed 0
5.00 Hz
Def: 5.00
Range: -10000 ... 10000
Set the multispeed values
02 /08
PAR: 11022
Multi speed 1
47.73 Hz
Def: 47.73 Hz
Range: -10000 ... 10000
03 /08
PAR: 11024
Multi speed 2
20.00 Hz
Def: 20.00 Hz
Range: -10000 ... 10000
04 /08
PAR: 11026
Multi speed 3
0.00 Hz
Def: 0.00 Hz
Range: -10000 ... 10000
05 /08
PAR: 11028
Multi speed 4
0.00 Hz
Def: 0.00 Hz
Range: -10000 ... 10000
06 /08
PAR: 11030
Multi speed 5
0.00 Hz
Def: 0.00 Hz
Range: -10000 ... 10000
07 /08
PAR: 11032
Multi speed 6
0.00 Hz
Def: 0.00 Hz
Range: -10000 ... 10000
08 /08
PAR: 11034
Multi speed 7
0.00 Hz
Def: 0.00 Hz
Range: -10000 ... 10000