EasyManua.ls Logo

Gehl RT175 - Switches;Indicators

Gehl RT175
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
Printed in U.S.A. 41 50940411/G0219
Hydraulic System
General
Thermostat Rating 82° C (180°F) cracking / 95° C (203°F) full open
85° C (185°F)
cracking / 95° C
(203°F) full open
Permissible Coolant Temp 110°C (230°F)
Fan Type / Ratio Pusher / 1 : 0.9 Pusher / 1:1.04 Pusher / 1 : 1.2
Applied Regulation
EPA
interim Tier 4
EPA Tier 4 final
EPA
interim Tier 4
EPA Tier 4 final
Aftertreatment System N/A DOC+DPF N/A DOC+DPF DOC
Starter - Power 3 kW - 12 V 3.2 kW - 12 V
Alternator Voltage / Amperage 12 V / 95 A
Operating Range– Ambient
Temperature
1
-15°C (+5°F) – +45°C (+113°F)
1. Operation above temperature range may result in overheating; operation below temperature range may result in hard-
starting.
Table 9: Engine
RT175
(interim Tier 4
Engine)
RT175
(Tier 4 Engine)
RT210
(interim Tier 4
Engine)
RT210
(Tier 4 Engine)
RT250
Table 10: Hydraulic System : General
RT175 RT210 RT250
Hydraulic Self-Leveling Hydraulic self-leveling in raise mode only. Full time-Standard; Switchable-Optional
Pump-to-Engine Ratio 1 : 1
System Pressure Setting 207 bar (3000 psi) @ 2500 rpm
207 bar (3000 psi) @ 2300
rpm
Optional High-Flow Auxiliary
Hydraulics System Pressure Setting
200 bar (2900 psi) @ 2500 rpm
200 bar (2900 psi) @ 2300
rpm
Port Relief Pressures
Boom Lift 241 bar (3500 psi)
Boom Lower 138 bar (2000 psi)
Tilt Rollback 241 bar (3500 psi)
Tilt Dump 241 bar (3500 psi)

Table of Contents

Related product manuals