GEM-P9600 Installation Instructions
L
NAPCO Security Systems
WI742D 5/03
!
Page 52
pervisory Failure) to central station will identify identifying the zone of the transmitter.
Zone ANDing, Groups 1–8 (Not for UL installations); Enable Local Alarm on First Zone “AND” Trip (Not for UL installations)
Up to 8 groups of at least two zones each can be “AND”ed, wherein the system will go into alarm only if any two zones of the group
are tripped within 2 minutes. This feature is designed to afford redundant protection for devices, such as glass break detectors, PIRs,
etc., that may show a tendency to false under certain conditions. Program each Group for any number of Zones available. All Zones
in any Group must be within the same Area. Do not mix 24-Hour Zones and non-24-Hour Zones within the same Group. Do not in-
clude a Panic Zone as part of any Group. Auto-Reset must be programmed for each Zone ANDing Zone. Note: Any zone that is
bypassed or goes into Swinger Shutdown will automatically disable Zone Anding for the entire Group. If “Enable Local Alarm on First
ZoneAND Trip” (Address 2419) is programmed, a trip on any Zone of the Group will cause an alarm output and alarm display at the
keypad; there will be no communication to the central station. Note: If "Enable CP-01 Limits" is enabled in EZ Programming, any
Zone in a Group will only activate an alarm and send a report ONCE. After the Zone has reported, it will remain in the Group and
may still initiate the Zone ANDing sequence.
Zone Area 1–Zone Area 8 See Areas
Zone Number on Pulse Alarm See Data Formats: Two-Digit Format
Zone Type
See Data Formats: Modem Formats
2-Wire, 4-Wire Smoke Detectors See Smoke Detectors
4-Wire Bus Failure
See Bus Failure
24-Hour Zone
A zone that provides protection at all times, whether or not the system is armed. If programmed for silent alarm (no Burg Output,
Aux. Output, Fire Output or Keypad Sounder on Alarm programmed) there will not be any indication on the keypad. If an Audible out-
put is programmed, the keypad will flash the red Armed LED and display “ALARM” followed by the zone description.
Note: Do not program a Day Zone as a 24-Hour Zone.
GLOSSARY

Other manuals for Gemini GEM-P9600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemini GEM-P9600 and is the answer not in the manual?

Gemini GEM-P9600 Specifications

General IconGeneral
BrandGemini
ModelGEM-P9600
CategorySecurity System
LanguageEnglish

Related product manuals