RXC-3000 Hardware Installation and User Guide
9000-0000-040 Revision 10 35 of 46 Genave Electronics
Real Time Clock
Triggering RXC-3000 From The Real Time Clock
Please refer to the Programming Guide 9000-0000-041 for more information
How To Adjust Time
Please refer to the Programming Guide 9000-0000-041 for more information
How To Set Daylight Savings Dates
Please refer to the Programming Guide 9000-0000-041 for more information
Real Time Clock Battery
The battery for the RTC is a standard 3 Volt CR1612, CR1616, CR1620 or CR1632 battery.
To maintain the current time, replace the battery with power applied to the RXC-3000.
Install the battery into the holder with the negative side facing into the board and the positive side
facing the holder.
A CR1616 battery will maintain correct time in the clock for up to 3 years.
The CR16XX series of batteries are available at most stores and pharmacies.
CR1616 Negative Side
CR1616 Positive Side