EasyManua.ls Logo

Generac Power Systems Guardian 5410 - Problem 7: Engine Cranks But Wont Start (LP)

Generac Power Systems Guardian 5410
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 6
TROUBLESHOOTING FLOWCHARTS
Page 29
REPLACE
DEFECTIVE
SWITCH
REPLACE BAD
STARTER
CONTACTOR
RELAY
REPLACE STARTER
MOTOR IF DEFECTIVE
REPLACE STARTER
CONTACTOR
GO TO PROBLEM 10
RECHARGE OR REPLACE BATTERY
– CLEAN, REPAIR OR REPLACE
BAD CABLE(S)
CHECK WIRING AND
WIRE CONNECTIONS.
REPAIR, RECONNECT
OR REPLACE BAD
WIRES AS REQUIRED
CHECK FOR
MECHANICAL BINDING
OF THE ENGINE OR
ROTOR
Problem 6 - Engine Will Not Crank
TEST 16 –
CHECK 7.5
AMP FUSE
TEST 17 – CHECK BATTERY & CABLES
(CHECK SW1 LED FOR LOW BATTERY
WARNING – 2 FLASHES)
BAD
BAD
FUSE BAD
FUSE BLOWS
REPLACE FUSE
BAD
BAD
BAD
BAD BAD
GOOD
GOOD
GOOD
GOOD
GOOD
GOOD
GOOD
TEST 20 –
CHECK
START-STOP
SWITCH
TEST 22 – CHECK
STARTER
CONTACTOR
RELAY
TEST 23 – CHECK
STARTER
CONTACTOR
TEST 21 – CHECK
POWER SUPPLY
TO WIRE 56
TEST 24 – CHECK
STARTER MOTOR
TEST 18 – CHECK
POWER SUPPLY
TO PRINTED
CIRCUIT BOARD
REPLACE
PRINTED CIRCUIT
BOARD

Table of Contents