MEGAFORCE 6500 Extended Life Generator
7
IMPORTANT: It is important to prevent gum deposits
from forming in essential fuel system parts, such as
the carburetor, fuel filter, fuel hose or tank during
storage. Also, experience indicates that
alcoholblended fuels (called gasohol, ethanol or
methanol) can attract moisture, which leads to
separation and formation of acids during storage.
Acidic gas can damage the fuel system of an engine
while in storage.
To avoid engine problems, the fuel system should be
emptied before storage of 30 days or longer. See
Storage on page 13. Never use engine or carburetor
cleaner products in the fuel tank or permanent
damage may occur.
OPERATING THE
GENERATOR
CAUTION! Never start or stop the engine with
electrical loads connected to the receptacles
AND with the connected devices turned ON.
Starting the Engine
DANGER! Never run engine indoors or in
enclosed poorly ventilated areas. Engine
exhaust contains carbon monoxide, an odorless
and deadly gas.
WARNING! Temperature of muffler and nearby
areas may exceed 150°F (65°C). Avoid these
areas.
Unplug all electrical loads from generator
receptacles before starting the engine.
Make sure the unit is in a level position.
Open the fuel shutoff valve (Figure 5).
Make sure the Idle Control switch is Off.
Place Run/Stop switch in the Run position
(Figure 6).
Place the choke lever in the Fullchoke position by
sliding it to the left in the direction indicated by the
arrow molded into the cover (Figure 7).
Grasp starter grip and pull slowly until you feel slight
resistance, then pull quickly. Do Not let handle
snap-back into recoil housing.
When engine starts, slowly move choke lever to the
Runposition (to the right) as the engine warms.
NOTE: If engine fails to start after 3 pulls, move the
choke lever to Halfchoke position and pull starter
rope again 2 times.
NOTE: If the engine still fails to start, review the
engine owners manual. Also, check for proper oil level
in crankcase. Unit is equipped with a low oil shutdown
system, as described in the engine owners manual.
Figure 6 Run/Stop Switch
Figure 5 Fuel Shut-off Valve
Figure 7  Choke Lever

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems MEGAFORCE 6500 and is the answer not in the manual?

Generac Power Systems MEGAFORCE 6500 Specifications

General IconGeneral
BrandGenerac Power Systems
ModelMEGAFORCE 6500
CategoryInverter
LanguageEnglish

Related product manuals