Loading...
CUBE
+
HYBRID 8,4m 4x150W LED
18
TL203-01-12-00
16-07-2018
Italiano - English
DISCOVER battery
YANMAR ENGINE
11.4 CENTRALINA IDRAULICA HYDRAULIC GEAR BOX
11.4.1 MOTORE ELETTRICO ELECTRICAL MOTOR
Alimentazione
230÷240 V 50-60 Hz ±
10%
Feeding
Potenza
0,55 kW
Power
Poli
4
Poles
Fattore di carico
S1
Duty factor
11.4.2 POMPA IDRAULICA GEAR PUMP
Cilindrata
1,3 cm
3
Displacement
Pressione massima
210 bar
Maximum pressure
Valore di pressione impostata dal
costruttore
180 bar
Factory setting pressure
Sistema di azionamento
d’emergenza
Manuale - Manual
Emergency action system
11.4.3 ELETTROVALVOLA UNLOADING SOLENOID VALVE
Isolamento termico della bobina
Class F VDE0585
Coil thermal insulation
Connessione elettrica
DIN 43650-A / ISO 4400
Electric connection
Grado di protezione
IP 65
Protection degree
Intermittenza
ED 100%
Coil duty cycle
Tensione della bobina
230 V 50-60 Hz ± 10%
Coil voltage
11.4.4 OLIO IDRAULICO HYDRAULIC FLUID
Capacità del serbatoio
5 l
Reservoir capacity
Tipo olio
ISO/DIN 6743/4
olio minerale - mineral oil
Fluid type
Viscosità olio
15-100 mm
2
sec
ISO 3448
Fluid viscosity
Temperatura olio
-15°C ÷ +80°C
Fluid temperature
Livello di contaminazione massimo
dell’olio
Classe 10 in accordo con
NAS 1638 con filtro
B 25 > 75 Class 10 in
accordance with NAS
1638 with filter B 25 > 75
Fluid maximum contamination
level