CUBE
+
HYBRID 8,4m 4x150W LED
71
TL203-01-12-00
16-07-2018
Italiano - English
DISCOVER battery
YANMAR ENGINE
ANOMALIA
ANOMALY
La macchina si ferma con l’indicatore luminoso
di bassa pressione olio acceso.
The unit stops with the oil low pressure signal
lamp ignited.
CAUSA
CAUSE
Il livello dell’olio è basso.
The oil level is low.
RIMEDIO
REMEDY
Verificare il livello e rabboccare se necessario.
Verify the level and add oil if necessary.
CAUSA
CAUSE
Il pressostato olio è difettoso.
The pressure switch is defective.
RIMEDIO
REMEDY
Sostituire il pressostato.
Replace the pressure switch.
CAUSA
CAUSE
La logica MPnano è difettosa.
The MPnano logic is defective.
RIMEDIO
REMEDY
Sostituire la logica.
Replace the logic.
ANOMALIA
ANOMALY
La macchina si ferma con l’indicatore luminoso
carica della batteria acceso.
The unit stops with the battery charge signal
lamp ignited.
CAUSA
CAUSE
La batteria è difettosa.
The battery is defective.
RIMEDIO
REMEDY
Sostituire la batteria.
Replace the battery.
CAUSA
CAUSE
L’alternatore del motore è guasto.
The engine’s alternator is failure.
RIMEDIO
REMEDY
Controllare ed eventualmente rivolgersi ad un
centro assistenza Yanmar.
Check it and eventually contact a Yanmar
assistance centre.
CAUSA
CAUSE
La logica MPnano è difettosa.
The MPnano logic is defective.
RIMEDIO
REMEDY
Sostituire la logica.
Replace the logic.