5. From the Resettable Sales Data screen,
highlight the Clear Data sub menu using
the ▼ (down) key and press the ↵ (Edit)
key. The LCD on the front of the machine
will display the screen as shown opposite,
warning the operator that all data will be
deleted.
Either press the ↵ (Edit) key to clear the data or press the X (Exit) key to
exit the menu without clearing the data.
7.1.3 Timed Events
1. From the Data Recall menu scroll down
and highlight Timed Events then press the
↵ (Edit) key. The LCD will display the
screen as shown opposite. From this menu
screen the operator can access then view
and record information relating to the four
events as shown.
2. To view the Power Losses screen, press
the ↵ (Edit) key. The screen displays a list
of the 10 most recent occasions when
power to the machine has been
disconnected in date, time of day and
period format. Press the X (Exit) key to
return to the Timed Events menu.
3. Press the
▼ (down) key to highlight Last Data Clear, Last Vend and Last
Clock Set. Information for these events is displayed along the bottom of
the screen.
7.1.4 Identification Numbers
From the Data Recall menu scroll down and
highlight Identification Numbers then press the
↵ (Edit) key. The LCD will display the screen as
shown opposite. From this menu the operator
can access and then view serial number, part
number and version type information relating
to the main PCB and any MDB coin/card mechanism fitted to the machine.
N.B. Coin Mechanism, Bill Validator and Card Reader will only be displayed if
an MDB device is fitted to the machine.