EasyManua.ls Logo

Geolux SmartObserver - Server, Modem, and Battery Settings

Default Icon
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SmartObserver User Manual
9
SmartObserver Data Logger
Server address
This is the address and the port to the Geolux Hydroview server that will receive the data from the data
logger. The address can be either a server name (such as www.hydro-view.com) or an IP address. The
default port is 80 and should be entered after the colon character (www.hydro-view.com:80).
Script path
This is the path to the server script which will receive the data when using SmartObserver with Geolux
Hydroview. This should be set to /send_data.
Mobile operator lock
The mobile operator lock denes the GPRS modem behavior when the home mobile network is not
available. The Default setting will allow the modem to connect to any available network, provided that
it is supported by the SIM card. The Disable roaming setting will disable roaming and ensure that no
roaming costs will be charged. The Lock to operator setting is the most restrictive and will allow the
modem to connect only to the home network.
Modem connection
Congure whether to connect to a standard GSM/GPRS mobile network or to use LTE-M connection.
This setting must be congured according to the SIM car used because some SIM cards support only
one type of connection.
Battery Settings
Charge current
The maximum charging current for the battery. Check the battery data sheet and ensure that this
parameter is not larger than the maximum charging current specied in the battery data sheet. It is
recommended to set this parameter to a value that is 10 percent lower than the maximum allowed
charging current.
Maximum charge voltage
This is the maximum charging voltage for the battery. Check the battery data sheet and enter the
specied value.
MPPT voltage
This is the voltage specied in the solar panel data sheet. It is the voltage level at which the charging of
the battery will start.