SMS Diagnostics
For diagnostic purposes the user can send SMS messages to the SmartObserver data logger. The
folowing messages are supported:
By sending a question mark ? to the SmartObserver data logger the user can view the modem
status and the data logger parameters. The response to the ? command has the following format:
GEOLUX LOGGER
ID:<logger_id>
APN:<gprs_apn>
NAME:<gprs_username>
PASS:<gprs_password>
SERVER:<server_address_port>
PATH:<script_path>
PATHFW:<script_path_fw_update>
CHRMA:<battery_charger_charge_mA>
CHRMV:<battery_charger_max_charge_mV>
MPPTMV:<battery_charger_mppt_mV>
CSTBYMMV:<battery_charger.cont_standby_mV>
MINCHRMA:<battery_charger.min_charge_mA>
NOCHRTEMP:<battery_charger.no_charge_temperature>
CHRENB:<battery_charger.enable_charging>
BLOBPWR:<do_not_turnoff_pwr_blob>
SENDALERTGPIO:<send_alert_on_gpio>
SIMLOCK:<mobile_operator_lock>
ModemStatus:<DiagnosticErrorMsg>,<gLastErrorMsg>
Sending the command RESET MEASURSTORAGE resets the saved measurements, while sending
the command RESET LOGGER performs a hard reset of the SmartObserver.
SMS messages can also be used to change the data logger’s parameters. To change a parameter
send the command CONFIG,<key1>=<value1>,<key2>=<value2>,...,<keyN>=<valueN>. The
following keys are used to change the parameters:
apn - gprs apn
usr - gprs username
pass - gprs password
serv - server address
path - script path
pathfw - rmware update path
sndalgpio - send gpio alert
simlock - mobile operator lock