53
Setting the end positions
Setting the opening angle from 90° to 18
Turn switching cam 2 of switch S2 counter clockwise (top view) by 90°.
Reconnect the actuator to the supply voltage
Move the actuator into position “CLOSED” (terminal 2 under current)
Turn cam 2 until reaching the desired position. (see position of the ball)
Replace the standard position indicator by the new 3-way position indi
-
cator
Standard position indicator 3-way position indicator
Setting the middle position
Move the actuator to the OPEN position (terminal 1 under current)
Place the additional switching cam on the shaft. For this, rst remove
the position indicator again and put it back on again in the same position
afterwards
Place cam 3 upon cam 2 (cam 4 still stays on top of the switches)
Put cam 3 into the same position as cam 2 and turn it clockwise by 90°
Move actuator to the “middle” position (terminal 3 under current)
Readjust cam 3 until reaching the desired middle position (see position
of the valve)
Now Place cam 4 upon cam 3 in the same position as cam 3. Adjust cam
4 afterwards. Its corner ank should activate switch S4 (S3 and S4 are
activated, the two nocks of the cams indicate to the opposite direction).
Close the actuator with the housing cover. The middle position is now
set.
OPEN MIDDLE CLOSED