54
7.5 Monitoring print
Description Technical data Code
Monitoring print 199 190 099
The monitoring print is mounted on the base board and is
connected electrically with a at cable. The monitoring print
enables ve functions:
1. Cycle time extension
2. Cycle time monitoring
3. Monitoring a selected maximum number of cycles
4. Monitoring a selected maximum of motor current
5. Position feedback signal 4-20mA (see page 26)
These monitor settings are made via the BCD switches 1 to
4. They are described in the following pages. The switches
must be plugged in order for the function to be active. The
functions work independently of one another. BCD switches
(1 to 4) can be connected individually.
Wiring diagram
BCD switch DIP switch
1. Cycle time extention (Vario)
2. Cycle time monitoring
3. Cycle counter
4. Current monitoring
5. Position feedback
1 5 2 3 4