EasyManuals Logo

GGP SV200 User Manual

Default Icon
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
SV200 R200
4/2007© by GLOBAL GARDEN PRODUCTS
2Check that the wire (2) runs freely inside the
sheath (1) when you move the lever.
3 Check that the end of the wire (2) is slightly
loose when you release the lawnmower lever.
B) Checking the ignition off microswitch
11 Disconnect the faston (11) from the coil.
12 Using an Ohmmeter tester, make contact with
the prods on terminals “1-COM” of the
microswitch (12) and engine earth connection;
the instrument should read:
= microswitch pressed
0 = microswitch free
Otherwise, replace the system for turning off
and stopping the engine [
6.7.D].
C) Checking the brake
21 Check that the clutch lining (13) is at least 2 mm
thick at the thinnest point.
22 Make sure that the control lever (14) moves
freely and remove any remains of grass and
mud.
23 Reconnect the petrol pipe and start the engine.
Release the lawnmower lever and check that
the engine stops within 3 seconds.
24 If it stops after 3 seconds, replace the entire
assembly [
6.7.D
], because the spring or
clutch lining is unable to guarantee the right
braking times.
WARNING! Never return the lawnmower to
your client without checking brake efficiency.
6.7.1
TURNING OFF AND STOPPING THE ENGINE
2 / 3

SERVICE MANUAL
page
from
2007to ••••
> 2 mm
11
12
13
14
<= ...BACK... <=