6.11 ELECTRICAL STARTING SYSTEM
AND RECHARGE ALTERNATOR
GENERAL INFORMATION
The electrical starting system consists of a motor
powered by a 12 Volt battery (fitted to the machine).
Battery recharging is assured by a coil alternator
that receives impulses from the engineís magnet fly-
wheel.
SERVICING PROCEDURES
A) Removing the starter motor
1 Remove the magnet flywheel [ 6.9.E].
2 Disconnect the connector (1) from the machi-
ne’s cabling.
3Disconnect the power cable (2) and earth cable
(3).
4 Unscrew the two screws (4) and remove the
starter motor (5).
5 Reverse the above operations to reassemble;
bear in mind the function of the three cables
when reconnecting the connector (1):
blue = recharge
red = starter motor power supply
black = earth
6 Remove the flywheel [
6.9.E]
B) Removing and cleaning
the starter motor pinion
11 Remove the starter motor [ 6.11.A].
12 With the help of a screwdriver turn the pinion
(11) and check that it can slide axially until it
compresses the spring (12).
13 Should deposits and dirt prevent complete
return proceed as follows:
6.11.0 - ELECTRICAL STARTING SYSTEM
AND RECHARGE ALTERNATOR
1 / 4

SERVICE MANUAL
page
from
2007 to ••••
4/2007© by GLOBAL GARDEN PRODUCTS
SV200 R200
1
2
4
3
4
5
11
12
<= ...BACK... <=