Conguring a RAID Set
B. Rebuilding an Array
Rebuilding is the process of restoring data to a hard drive from other drives in the array. Rebuilding applies
only to fault-tolerant arrays such as RAID 1 and RAID 10 arrays. To replace the old drive, make sure to use a
new drive of equal or greater capacity. The procedures below assume a new drive is added to replace a failed
drive to rebuild a RAID 1 array.
While in the operating system, make sure the Chipset and RAID drivers have been installed. Then double-click
the RAIDXpert2 icon on the desktop to launch the RAID utility.
Step 1:
Enter the login ID and password (default: "admin"),
and then click Submit to launch AMD RAIDXpert2.
Step 2:
In the Disk Devices section, left-click your mouse
twice on the newly-added hard drive.
Step 3:
On the next screen, select Assign as Global Spare
and click Conrm.
Step 4:
During the rebuild process, you can select the array
that is being built (displayed in red) in the Active
Volumes section to check the current progress.
Step 5:
Then rebuild is complete when the Task State
column shows "COMPLETED."

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GIGA-BYTE TECHNOLOGY X570S AORUS MASTER and is the answer not in the manual?

GIGA-BYTE TECHNOLOGY X570S AORUS MASTER Specifications

General IconGeneral
BrandGIGA-BYTE TECHNOLOGY
ModelX570S AORUS MASTER
CategoryMotherboard
LanguageEnglish

Related product manuals