Gill Instruments Ltd
Intrinsically Safe WindObserver Anemometer Page 9 Issue 10
Doc. No. 1360-PS-0001 May 2015
4.3 Power Supply Unit 1360-PK-055 (1954-00-002)
Mounted in Non Hazardous Area.
I.S. LVPCI may be used with either Model 1360 IS Anemometer (SIRA 00ATEX2218, IECEx SIR
13.0157) or IS II Anemometer (SIRA 15ATEX2014 and IECEx SIR 13.0013).
I.S. Rating – ATEX European, IECEX International.
NOT for use in Zone 0, 1 and 2 Areas (Non Hazardous Area Use Only).
See ATEX and IECEX Certificates in Appendix 2.
Input and Outputs
Digital Input RS422 Interface (Data to/from IS WindObserver connected via
galvanic isolation).
Digital Outputs RS232 and RS422 Interface (Data to/from IS WindObserver)
Power Requirement
Input Power 9v to 30v dc at 200mA max (Fused 20mm, 1 amp, anti-surge).
Galvanic isolation between input power and anemometer supply.
Output Power 10.5v dc at 50mA to IS WindObserver (fused 100mA)
Dimensions
Size See page 13 for dimensions.
Weight 2.4kg.
Materials
External Construction Fibox Euronord Polyester
Environmental
Moisture protection IP54
Ambient Operating temperature -30°C to +40°C
Storage Temperature -50°C to +75°C
Humidity 5% to 90% RH
EMC Emissions and Immunity EN 61326-2-1:2013
EN 61204-3:2000
Emissions EN 60945:2002 Clause 9
Immunity EN 60945:2002 Clause 10
Intrinsic Safety
EN60079-0:2012
EN60079-11:2012
EN60079-26:2007
IEC60079-0:2011 Edition 6.0
IEC60079-11:2011 Edition 6.0
IEC60079-26:2006 Editions 2.0
Standards Traceable to UK national standards
Site Calibration None required.