WindSonic Doc No 1405 PS 0019 Issue 28 November 2019
69
14.6 Gill Output Message Format
a13GillInst 2487 B06 1120012
Under normal no error conditions a typical data output will show:-
0+083+000.02+00<CR><LF> e.g. Unit ID, Direction, Speed, Status Code.
Under error conditions e.g. blocked paths error code 04 the unit will pad the wind data
with 9’s as follows (Gill Fixed Field setting):-.
0+999+999.9+04<CR><LF> e.g. Unit ID, Direction, Speed, Status Code.
14.7 SDI-12 Status Codes
Sufficient samples in average period
Insufficient samples in average period on U axis
Insufficient samples in average period on V axis
Insufficient samples in average period on both axes
Measurement
average building
Will be output up to 68 seconds after power up whilst
initialisation and 1 minute averaging calculations take place
when in High Power mode.
Gill WindSonic
Software Version
Gill WindSonic
Serial Number