PROBLEM:
The motor side of the awning closes when the awning is retracted bot the opposite end
does not.
SOLUTION:
Refer to “Adjusting the Lead Rail” on page 23. If this does not solve the issue please call
the Girard Systems service line at (949)259-4000 or toll free at (800)382-8442.
PROBLEM:
Motor will not operate.
SOLUTION:
Check that all of the GFI switches in the vehicle are turned on. If your vehicle has a
Awnings Power Main Swtch, locate that switch and make sure it is in the ON position.
The 110V AC motor supplied in your NOVA Awning is designed for intermittent use and
may cut out temporarily if it has overheated. When this occurs you must allow the
motor to cool so that the internal circuit breaker can reset. This may take up to an hour
depending on the outside temperature. You may use a manual crank during this period.
If this does not solve the issue please call the Girard Systems service line at
(949)259-4000 or toll free at (800)382-8442.
PROBLEM:
The motor will operate for 10-12” and then stop.
SOLUTION:
The motor may not be receiving enough amps (inverter power is low) to operate
correctly. Check to ensure that you have a minimum of 10 amps, if not turn on the
generator or switch to a shore connection. If this does not solve the issue please call the
Girard Systems service line at (949)259-4000 or toll free at (800)382-8442.
PROBLEM:
31