allow the motor to cool so that the internal circuit breaker can reset. This may
take up to an hour depending on the outside temperature. You may use a
manual crank during this period.
•
If this does not solve the issue please call the Girard Systems service line at
(949)259-4000 or toll free at (800)382-8442.
PROBLEM:
The motor will operate for 10-12” and then stop.
SOLUTION:
The motor may not be receiving enough power to operate correctly.
•
Check to ensure that you have a minimum of 10 amps, if not switch on your
generator or connect to shore power.
•
If this does not solve the issue please call the Girard Systems service line at
(949)259-4000 or toll free at (800)382-8442.
PROBLEM:
The fabric is loose when the awning is fully extended; i.e. the roller keeps turning after
the awning arms have locked open.
SOLUTION:
The motor’s OUT limits must be reset to factory standards. Please refer to the
“Adjusting the Motors Limit Switches” section on page 16-17.
PROBLEM:
The motor stops before the lead rail has closed completely into the awning cassette on
either or both sides. There is no apparent binding of the awning components.
SOLUTION:
The VISION Awning is equipped with a manual override motor which has manual limit
settings. The IN limit may need to be adjusted to allow the box to be closed tighter.
Refer to the “Adjusting the Motors Limit Switches” section of this manual.
PROBLEM:
As the awning is closing, the elbow of one or more of the arms is hanging down
preventing the case from closing.
SOLUTION:
Please refer to the “Adjusting pitch” section of this manual.