EasyManua.ls Logo

Glow-worm ENERGY 25c - 10.6 Removing the gas-air mixture unit; 10.7 Cleaning the heat exchanger

Glow-worm ENERGY 25c
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Inspection and maintenance
24 Installation and maintenance instructions ENERGY 0020177746_03
10.6 Removing the gas-air mixture unit
Note
The gas-air mixture unit consists of three main
components:
Fan
Gas valve,
Burner cover
1. Switch off the product via the main switch.
2. Close the gas isolator cock.
3. Remove the front casing. ( Page 10)
C
A
B
1
D
2
4. Remove the screw (1).
5. Push the clip upwards.
6. Remove the flue gas pipe (2).
3
4
5
A
B
7. Remove the air intake pipe (3).
8. Remove the plugs from the gas valve (4) and from the
fan (5).
A
C
D
B
6
9. Remove the gas-air mixture unit (6).
7
7
8
10. Remove the burner seals (7) and the burner (8).
11. Check the burner and the heat exchanger for damage
and dirt.
12. If necessary, clean or replace the components accord-
ing to the following sections.
13. Install the two new burner seals.
10.7 Cleaning the heat exchanger
1
1. Protect the folded down electronics box against sprayed
water.
2. Clean the ribs of the heat exchanger (1) with water.
The water runs out into the condensate tray.

Table of Contents