Appendix
46 Installation and maintenance instructions ENERGY 0020177746_03
J Pipe lengths for the air/flue pipe
J.1 Length of the C13 type air/flue pipe
Applicability: C13 type air/flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L) Dia. 80/125 (L)
C13 type air/flue
pipe
C13 type air/flue
pipe
ENERGY 25c -A
(H-GB)
≤ 10 m ≤ 25 m
ENERGY 30c -A
(H-GB)
≤ 10 m ≤ 25 m
ENERGY 35c -A
(H-GB)
≤ 10 m ≤ 25 m
J.2 Length of the C33 type air/flue pipe
Applicability: C33 type air/flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L) Dia. 80/125 (L)
C33 type air/flue
pipe
C33 type air/flue
pipe
ENERGY 25c -A
(H-GB)
≤ 10 m ≤ 25 m
ENERGY 30c -A
(H-GB)
≤ 10 m ≤ 25 m
ENERGY 35c -A
(H-GB)
≤ 10 m ≤ 25 m
J.3 Length of the C43 type air/flue pipe
Applicability: C43 type air/flue pipe
Diameter of the
air/flue pipe
Dia. 60/100 (L)
C43 type air/flue
pipe
ENERGY 25c -A
(H-GB)
≤ 5 m
ENERGY 30c -A
(H-GB)
≤ 5 m
ENERGY 35c -A
(H-GB)
≤ 5 m
K Technical data
Technical data – Heating
ENERGY 25c -A (H-
GB)
ENERGY 30c -A (H-
GB)
ENERGY 35c -A (H-
GB)
Max. flow temperature adjustment
range (default setting: 75 °C)
10 … 80 ℃ 10 … 80 ℃ 10 … 80 ℃
Maximum permissible pressure
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
Nominal water flow (ΔT = 20 K)
788 l/h 1,094 l/h 1,102 l/h
Nominal water flow (ΔT = 30 K)
525 l/h 729 l/h 876 l/h