51
CONDENSATE
TRAP
SECURING
SCREW
SERVICE
FILL LEVEL
14 Replacement of Parts
Diagram 14.12
12810
14.15 Condense Trap
For access, refer to section 14.1.
Remove the drain outlet pipe from the base of the trap. Re-
move the condensate drain securing screw and carefully pull
the trap forward, see diagram 14.12.
On the condensate trap there is a key symbol that should be
in line with the locked padlock symbol on the condense drain.
To remove the trap turn in the direction indicated, see diagram
14.12, toward the unlock symbol and carefully pull down clear
of the condense drain.
Remove any solids found in the condense trap.
Flush water through the trap to remove any remaining solids.
Check for any debris in the outlet pipe of the condensate drain
and clean as necessary.
Reassemble and refit the condense trap.
14.16 Heating Flow Thermistor
For access refer to section 14.1
Remove the silencer front, fan/gas valve assembly and flue
hood for access. See relevant sections.
Refer to diagram 14.13.
Remove the electrical connections from the thermistor.
Remove the retaining clip from the flow pipe.
Remove the thermistor from the retaining clip.
Note that the polarity of the wiring to thermistors is unimpor-
tant.
HEATING FLOW
THERMISTOR
FLOW PIPE
Diagram 14.14
Diagram 14.13
13027
14.17 Heating Return Thermistor
For access, refer to section 14.1.
Refer to diagram 14.14.
Remove the electrical connections from the thermistor.
Remove the retaining clip from the return pipe.
Remove the thermistor from the retaining clip.
Note that the polarity of the wiring to thermistor is unimportant.
HEAT RETURN
THERMISTOR
13060

Other manuals for Glow-worm Flexicom 24cx

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Flexicom 24cx and is the answer not in the manual?

Glow-worm Flexicom 24cx Specifications

General IconGeneral
Boiler TypeCombi
Fuel TypeNatural Gas
Central Heating Output24 kW
DHW Flow Rate9.8 l/min
ErP Efficiency RatingA
Central Heating Flow Temperature Range30 - 80°C
Weight31 kg
Warranty2 years

Related product manuals