1010 1111
Network
Ethernet 802.3
10M / 100M, Full-Duplex or Half-Duplex
DHCP or static IP address
WiFi station 802.11
b/g/n 2,4GHz
Supported encodings: open / WEP / WPA / WPA2 / WPA3
up to 10 congurations can be saved
DHCP or static IP address
WiFi Access Point
for local connection with the app or API
Channel freely adjustable from 1 - 13
SSID and password adjustable
deactivatable
Interfaces and features
Possible in the local network Cloud connection
Modbus TCP API yes not possible
MQTT API
yes, connections in local networks
and to the internet possible
not possible
HTTP API
yes yes
Connection to go-e Chargers
(HOME series V3 and Gemini
series)
yes, number not limited
Optional data transmission via cloud
possible (necessary if not in the
same subnet or separated by NAT)
Connection to go-e Chargers
(HOME series V2)
no
Cloud connection at go-e Charger
HOME V2 and go-e Controller has to
be established
Dynamic load balancing
yes, local transmission
of measured values
Cloud connection on the
go-e Charger must exist
go-e app
yes, automatically nds go-e
Charger in local network with mDNS
yes, remote access with serial
number and password input
Log data recording and export
with measured values
not via the go-e app / go-e cloud /
display. Own data acquisition via
API possible
yes
Graphical representation of the
power consumption in the past
not via the go-e app / go-e cloud /
display. Own data acquisition via
API possible
yes
Measurement functions: nominal voltage
Min Nominal Max
L1 - PE
L2 - PE
L3 - PE
230 V 277 V
L1 - N 100 V 230 V 277 V
L1 - L2
L1 - L3
L2 - L3
400 V
Inputs for current measurement
Sinus RMS Peak
max. measurable current 100 A 144 A
max. permanent current
(thermally limited)
140 A
Product specications
Dimensions (W x H x D) approx. 72 x 90 (without plugs) x 61 mm (4 division units)
Weight 193 g
Voltage measurement
4 inputs
three-phase (L1, L2, L3 and N)
single-phase (L1 and N)
Nominal voltage 3 x 230 V (single-phase) / 400 V (three-phase)
Nominal frequency 50 Hz
Display Color display
Compatibility
go-eCharger Home series
go-e Charger Gemini series
All PV inverters*
All AC battery storage systems
7. Technical data
*PV optimisation is also possible without direct measurement of production by the inverter. Own production can
be measured and visualised via a sensor for AC inverters only.