4.4 WARNING QUICK CHECK LIST
[1] Inverter cannot be installed near flammable, explosive or strong electro-magnetic equipment,
page 06
[2] Remember that this inverter is heavy! Please be careful when lifting out from the package,
page 07
[3] The polarity of PV strings or on the inverter cannot be connected by reversely, otherwise
inverter could be damaged, page 08
[4] Make sure battery breaker is off and battery nominal voltage meet EH specification before
connecting battery to inverter and make sure inverter is totally isolated from PV and AC power,
page 09
[5] Make sure inverter is totally isolated from any DC or AC power before connecting AC cable,
page 11
[6] Make sure AC cable is totally isolated from AC power before connecting Smart Meter & CT,
page 13
*2: The grid feed in power for VDE-AR-N 4105 and NRS097-2-1 is limited 4600VA, for AS/NZS 4777.2 is limited 4950VA &
21.7A.
*3: CAN communication is configured by default. If 485 communication is used, please replace the corresponding
communication line.
*4: No Back-up Output.
*5: Not all certifications & standards listed, check the official website for details.
• For Australia requirements, in the THDi test, there should add Zref between inverter and mains.
RA, XA for Line conductor
RN, XN for Neutral conductor
Zref:
RA=0,24;XA=j0,I5 at 50Hz;
RN=0,I6;XN=j0,10 at 50Hz.
Applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a low level
Overvoltage Category Definition
Moisture Location Category Definition
Category Ⅰ
Category Ⅱ
Category Ⅲ
Category Ⅳ
Moisture Parameters
Level
0~+40℃
5%~85% 15%~100% 4%~100%
-33~+40℃ -20~+55℃
3K3 4K2 4K4H
Temperature Range
Humidity Range
Applies to a fixed equipment downstream of and including the main distribution board. Examples are switchgear and other
equipment in an industrial installation
Applies to equipment permanently connected at the origin of an installation (upstream of the main distribution board). Example
are electricity meters, primary over-current protection equipment and other equipment connected directly to outdoor open
lines
Applies to equipment not permanently connected to the installation. Examples are appliances, portables tools and other
plug- connected equipment