User Manual
Hybrid Inverter
EH Series/EH Plus Series
3.6-6kW
V1.4-2022-8-30

Other manuals for Goodwe EH Series

Questions and Answers

  • M
    Melissa HarrisonSep 8, 2025
    What does Large DC of AC current L1 mean on my Goodwe EH Inverter?
    • A
      Amber RogersSep 8, 2025
      A 'Large DC of AC current L1' error on your Goodwe Inverter indicates that the DC component of the output current exceeds the safety or default range. If the problem is caused by an external fault like a utility grid exception or frequency exception, the inverter will recover automatically after solving the problem.
  • R
    Robert MedinaAug 23, 2025
    What causes a Grid Overfrequency error on a Goodwe EH?
    • S
      Stephanie WilsonAug 23, 2025
      A 'Grid Overfrequency' error on your Goodwe Inverter indicates a utility grid exception where the actual grid frequency exceeds the local grid standard's requirements. If this happens occasionally, it might be a temporary issue, and the inverter should recover automatically. However, if it occurs frequently, check if the grid frequency is within the permissible range. If the grid frequency exceeds the permissible range, contact your local power company. If the grid frequency is within the permissible range, you may need to modify the overfrequency protection threshold or disable the overfrequency protection function after obtaining consent from the local power company.
  • D
    Deborah WatsonAug 25, 2025
    Why does my Goodwe EH display a Grid Undervoltage error?
    • A
      Amanda RuizAug 26, 2025
      The 'Grid Undervoltage' error on your Goodwe Inverter means the grid voltage is lower than the permissible range, or the duration of low voltage exceeds the requirement of LVRT. If this occurs occasionally, it may be a temporary grid issue, and the inverter should recover automatically once the grid is normal. If it occurs frequently, check whether the grid voltage is within the permissible range. If the grid voltage is not within the permissible range, contact the local power company. If the grid frequency is within the permissible range, modify the undervoltage protection threshold, LVRT, or disable the undervoltage protection function, but only after getting approval from the local power company. Also, make sure the AC breaker and output cables are securely and correctly connected.
  • L
    leelewisAug 26, 2025
    What should I do if my Goodwe EH Inverter shows a Grid Rapid Overvoltage error?
    • M
      Mario McdonaldAug 27, 2025
      A 'Grid Rapid Overvoltage' error on your Goodwe Inverter indicates an abnormal or ultra-high grid voltage. If this occurs occasionally, it may be a temporary utility grid issue, and the inverter will recover automatically once the grid returns to normal. If it happens frequently, check if the grid voltage is within the permissible range. If the grid voltage exceeds the permissible range, contact the local power company. If the grid voltage is within the permissible range, modify the grid overvoltage rapid protection threshold only after obtaining consent from the local power company.
  • C
    camposderekAug 27, 2025
    What does a Grid Underfrequency error mean on my Goodwe EH?
    • O
      ograyAug 27, 2025
      A 'Grid Underfrequency' error on your Goodwe Inverter indicates a utility grid exception where the actual grid frequency is lower than the local grid standard's requirement. If the problem occurs occasionally, the utility grid may be temporarily abnormal, and the inverter will recover automatically after detecting that the utility grid is normal. If the problem occurs frequently, check whether the grid frequency is within the permissible range. If the grid frequency exceeds the permissible range, contact the local power company. If the grid frequency is within the permissible range, modify the underfrequency protection threshold or disable the underfrequency protection function after obtaining the consent of the local power company.
  • S
    Scott HallSep 22, 2025
    What does Flash Fault mean on my Goodwe EH?
    • W
      William HunterSep 22, 2025
      Flash Fault on Goodwe Inverter means that the internal Flash storage is abnormal. To solve this problem, disconnect the AC output switch and DC input switch, then connect them 5 minutes later.
  • J
    Jesse HuffmanSep 16, 2025
    What does AC HCT Check abnormal mean on my Goodwe Inverter?
    • G
      Gina ToddSep 16, 2025
      AC HCT Check abnormal on Goodwe Inverter means that the sampling of the AC HCT is abnormal. To solve this problem, disconnect the AC output switch and DC input switch, then connect them 5 minutes later.
  • V
    Veronica DunlapSep 18, 2025
    What does GFCI HCT Check abnormal mean on my Goodwe EH?
    • M
      Molly CookSep 18, 2025
      GFCI HCT Check abnormal on Goodwe Inverter means that the sampling of the GFCI HCT is abnormal. To solve this problem, disconnect the AC output switch and DC input switch, then connect them 5 minutes later.
  • R
    russellstephenSep 7, 2025
    What does Grid Frequency Instability mean on my Goodwe EH Inverter?
    • J
      Jessica MccannSep 7, 2025
      A 'Grid Frequency Instability' error on your Goodwe Inverter indicates a utility grid exception where the actual grid frequency change rate does not meet the local grid standard's requirements. If this occurs occasionally, the utility grid may be temporarily abnormal, and the inverter will recover automatically after detecting that the utility grid is normal. If the problem occurs frequently, check whether the grid frequency is within the permissible range. If the grid frequency exceeds the permissible range, contact the local power company.
  • W
    whitesarahSep 4, 2025
    What to do if my Goodwe EH shows an Abnormal Ground error?
    • S
      Susan PerrySep 4, 2025
      An 'Abnormal Ground' error on your Goodwe Inverter can be caused by: 1. A poorly connected PE cable on the inverter. 2. Reversed L and N cable connections when the PV string output is grounded. To resolve this, check: 1. That the inverter's PE cable is properly connected. 2. Whether the L and N cables are reversed if the PV string output is grounded.

Summary

Safety Precautions

General Safety Guidelines

Fundamental safety rules for operating and installing the inverter.

PV String Safety

Safety measures for connecting photovoltaic strings.

Inverter Safety

Specific safety instructions for the inverter unit.

Battery Safety

Precautions for safe handling and connection of the battery.

Product Introduction

System Working Modes

Explains the different operational modes: Economic, Self-consumption, Back-up.

Installation

Installation Environment Requirements

Specifies site conditions: ventilation, temperature, humidity, altitude, interference.

Electrical Connection

Electrical Connection Safety

Critical safety rules and best practices for electrical connections.

DC Input Cable Connection

Procedures for connecting the photovoltaic DC input cables.

Battery Cable Connection

Steps for securely connecting the battery cables to the inverter.

AC Cable Connection

Guidelines for connecting the AC power cables for grid-tied and back-up operation.

Equipment Commissioning

System Commissioning

Maintenance & Troubleshooting

Powering Off Procedures

Step-by-step instructions to safely de-energize the inverter.

Troubleshooting Common Issues

Lists common faults, their causes, and recommended solutions.

Goodwe EH Series Specifications

General IconGeneral
TypeHybrid Inverter
Number of MPPTs2
THDi<3%
DC SwitchIntegrated
Protection DegreeIP65
Max. Charging/Discharging Power5kW
Battery Voltage Range40V to 60V
Nominal AC Voltage230V
Operating Temperature Range-25°C to 60°C
Cooling MethodNatural Convection
CommunicationRS485
Battery TypeLithium
AC Output Voltage230V
AC Output Frequency50/60 Hz