NS & DNS Series INTRODUCTION
V2.0

Other manuals for Goodwe GW5000D-NS

Questions and Answers

  • K
    kristahoffmanSep 22, 2025
    What to do if my Goodwe Inverter displays a Fac Failure?
    • B
      Brent JohnstonSep 22, 2025
      If your Goodwe Inverter displays a 'Fac Failure', the grid may not be connected. Check the grid connection cables and verify the grid's availability.
  • J
    Jonathan LopezSep 23, 2025
    What to do if my Goodwe GW5000D-NS displays a Vac Failure?
    • T
      Todd TrujilloSep 23, 2025
      If your Goodwe Inverter shows a 'Vac Failure', the inverter will automatically restart within 5 minutes if the grid returns to normal. Ensure the grid voltage meets the required specifications and that the neutral (N) and PE wires are securely connected. If problems continue, contact your local service office.
  • N
    nbrownSep 23, 2025
    What to do if my Goodwe GW5000D-NS indicates a Utility Loss?
    • B
      Brandi JonesSep 23, 2025
      If your Goodwe Inverter shows a 'Utility Loss', first, make sure that the inverter is connected to the grid. Then, check the cable connection to the power grid and confirm the power grid's availability.
  • A
    Aaron WilliamsSep 23, 2025
    What to do if my Goodwe GW5000D-NS Inverter shows PV Over Voltage?
    • C
      Craig WilliamsSep 23, 2025
      If your Goodwe Inverter shows a 'PV Over Voltage' error, start by checking if the PV open circuit voltage is too close to, or exceeds, the maximum input voltage. If the problem remains even when the PV voltage is below the maximum input voltage, contact your local service office for further assistance.
  • J
    Jeffrey FisherSep 23, 2025
    What to do if my Goodwe GW5000D-NS Inverter is Over Temperature?
    • C
      Connor LopezSep 23, 2025
      If your Goodwe Inverter is showing an 'Over Temperature' warning, it means the internal temperature is higher than the specified normal value. Try to reduce the ambient temperature and move the inverter to a cooler location. If the issue continues, contact your local service office.
  • K
    Kelly OliverAug 31, 2025
    What to do if my Goodwe GW5000D-NS displays 'Ground I Failure'?
    • K
      Krystal JohnstonAug 31, 2025
      If your Goodwe inverter reports a 'Ground I Failure' because the ground current is too high, follow these steps: 1. Unplug the inputs from the PV generator and inspect the peripheral AC system. 2. After resolving the issue, reconnect the PV panel and check the inverter status. 3. If the problem continues, contact your local service office for assistance.
  • W
    wilsoncharlesAug 25, 2025
    What causes Over Temperature error on Goodwe Inverter and how to fix it?
    • S
      Sara ColeAug 25, 2025
      The 'Over Temperature' error on your Goodwe Inverter indicates that the internal temperature is higher than normal. Try to decrease the ambient temperature or move the inverter to a cooler location.
  • S
    snyderfaithAug 25, 2025
    Why does my Goodwe Inverter show Utility Loss?
    • S
      Scott SullivanAug 26, 2025
      A 'Utility Loss' message on your Goodwe Inverter indicates a disconnection from the power grid. Check if the power grid is connected to the cable and verify the availability of the power grid.
  • P
    pwilkinsonAug 26, 2025
    What to do if my Goodwe GW5000D-NS displays PV Over Voltage?
    • P
      Pamela WarnerAug 26, 2025
      If your Goodwe Inverter is showing a 'PV Over Voltage' error, check if the PV open circuit voltage is higher than or too close to the maximum input voltage.
  • L
    Lisa StevensAug 27, 2025
    What does Isolation Failure mean on my Goodwe GW5000D-NS and how can I resolve it?
    • C
      Carlos SandersAug 27, 2025
      An 'Isolation Failure' on your Goodwe Inverter suggests a problem with the impedance between the ground and PV (+) & PV (-). Check the impedance; the value must be greater than 100kΩ. Also, ensure the inverter is properly grounded.

Summary

NS & DNS Series Introduction

Product Introduction

Overview of GoodWe NS & DNS series inverters, highlighting technology, design, and size.

Development Background

Explains the evolution of single-phase inverters and compares SS/DS with NS/DNS series.

New Product Feature

Details key features like safety, lower start-up voltage, and integrated communication.

Installation and Operation Guide

Installation Guide

Instructions for mounting, package contents, and selecting installation locations.

Booting-Up Process

Step-by-step guide for starting up the inverter and configuring WiFi monitoring.

Internal Structure

Block diagrams illustrating the internal components of NS and DNS series inverters.

Trouble Shooting

Common error codes, causes, and measurement procedures for troubleshooting inverter issues.

Technical Data, Certifications, and Service

Technical Data

Detailed specifications for NS and DNS series inverters, including DC/AC input/output and efficiencies.

Certifications

Overview of product certifications and approvals across different regions and standards.

Warranty & Service

Information on standard warranty conditions, exceptions, and after-sales service policies.

Goodwe GW5000D-NS Specifications

General IconGeneral
ModelGW5000D-NS
Rated Power5000 W
Max. DC Input Power6500W
Number of MPPT2
Max. Input Current per MPPT13 A
Rated AC Output Power5000 W
Max. AC Apparent Power5500 VA
AC Voltage Range180-280V
Total Harmonic Distortion (THD)<3%
DC SwitchYes
Protection ClassIP65
Protection LevelIP65
Rated Output Voltage230 V
AC Output Voltage230 V
Rated Grid Frequency50 Hz
AC Output Frequency50 Hz
Power Factor>0.99
Operating Temperature Range-25°C to 60°C
Cooling MethodNatural Convection