Questions and Answers

  • M
    Marissa LopezAug 27, 2025
    How to fix a Relay-Check Failure on a Goodwe GW5000D-NS Inverter?
    • M
      Melody VelazquezAug 27, 2025
      To address a Relay-Check Failure on your Goodwe Inverter: 1. Turn off the DC switch of the inverter. 2. Wait until the LCD light is off. 3. Turn on the DC switch and ensure it is connected.
  • T
    Todd JonesAug 27, 2025
    What does Fac Failure mean on Goodwe Inverter?
    • S
      Sharon WilliamsAug 27, 2025
      A 'Fac Failure' on your Goodwe Inverter means it is not connected to the grid. Check if the power grid is connected to the cable, and check the availability of the power grid.
  • K
    Kevin BrooksAug 28, 2025
    What does Ground I Failure mean on Goodwe GW5000D-NS, and how can it be fixed?
    • B
      Bryce AndersonAug 28, 2025
      A 'Ground I Failure' on your Goodwe Inverter indicates that the ground current is too high. Unplug the inputs from the PV generator and check the peripheral AC system. Once the problem is resolved, reconnect the PV panel and check the inverter status.
  • G
    Gerald LevineAug 28, 2025
    What to do if my Goodwe GW5000D-NS has no display?
    • A
      alexandracolonAug 28, 2025
      If your Goodwe Inverter's display is not working: 1. Turn off the DC switch and unplug the DC connector, then measure the voltage of the PV array. 2. Plug in the DC connector and turn on the DC switch. 3. If the PV array voltage is lower than 250V, check the configuration of the inverter module.
  • J
    Jessica JohnsonAug 29, 2025
    What to do if my Goodwe Inverter shows 'Isolation Failure'?
    • A
      ashley40Aug 29, 2025
      If your Goodwe inverter displays an 'Isolation Failure', follow these steps: 1. Check the impedance between the ground and PV (+) & PV (-). The impedance value must be greater than 100kΩ. Ensure the inverter is properly grounded. 2. If the problem persists, contact your local service office for assistance. Additionally, the inverter has a built-in buzzer that will sound continuously for 1 minute upon failure. If the fault isn't resolved, the buzzer will sound every 30 minutes. You can also add the inverter to a monitoring platform and set up alarm reminders to receive email notifications about alarm information.
  • J
    James HesterAug 30, 2025
    What to do if my Goodwe GW5000D-NS Inverter displays 'Vac Failure'?
    • M
      Matthew JonesAug 30, 2025
      If your Goodwe inverter is showing a 'Vac Failure', here are some things to check: 1. The PV Inverter will automatically restart within 5 minutes if the grid returns to normal. 2. Ensure that the grid voltage conforms to the specified requirements. 3. Verify that the neutral (N) wire and PE cable are properly connected. 4. If the problem persists, contact your local service office for further assistance.
  • Z
    Zachary JonesAug 30, 2025
    What to do if my Goodwe Inverter displays 'Utility Loss'?
    • W
      William MillerAug 30, 2025
      If your Goodwe inverter indicates a 'Utility Loss', please check the following: 1. Ensure the inverter is properly connected to the power grid. 2. Verify that the power grid is connected to the cable. 3. Confirm the availability of the power grid.
  • C
    cdavidsonAug 25, 2025
    What to do if my Goodwe Inverter shows a Vac Failure?
    • B
      brownryanAug 25, 2025
      If your Goodwe Inverter displays a Vac Failure, it means there's an issue with the grid voltage. First, the inverter will automatically restart within 5 minutes if the grid returns to normal. Ensure the grid voltage conforms to the specified requirements. Also, verify that the neutral (N) wire and PE cable are securely connected.
  • M
    matthew59Aug 31, 2025
    What to do if my Goodwe Inverter displays 'PV Over Voltage'?
    • T
      Tina BrownSep 1, 2025
      If your Goodwe inverter is showing a 'PV Over Voltage' error: 1. Check if the PV open circuit voltage is higher than or too close to the maximum input voltage. 2. If the issue persists even when the PV voltage is less than the maximum input voltage, contact your local service office for assistance.
  • M
    Mrs. Julie FinleySep 1, 2025
    Why does my Goodwe GW5000D-NS have no display?
    • R
      roger88Sep 1, 2025
      If your Goodwe inverter's display is not working, try these steps: 1. Turn off the DC switch and unplug the DC connector, then measure the voltage of the PV array. 2. Plug in the DC connector and turn on the DC switch. 3. If the PV array voltage is lower than 250V, check the configuration of the inverter module. 4. If the voltage is higher than 250V, contact your local service office for assistance.

Summary

NS & DNS Series Introduction

Product Introduction

Overview of GoodWe NS & DNS series inverters, highlighting technology, design, and size.

Development Background

Explains the evolution of single-phase inverters and compares SS/DS with NS/DNS series.

New Product Feature

Details key features like safety, lower start-up voltage, and integrated communication.

Installation and Operation Guide

Installation Guide

Instructions for mounting, package contents, and selecting installation locations.

Booting-Up Process

Step-by-step guide for starting up the inverter and configuring WiFi monitoring.

Internal Structure

Block diagrams illustrating the internal components of NS and DNS series inverters.

Trouble Shooting

Common error codes, causes, and measurement procedures for troubleshooting inverter issues.

Technical Data, Certifications, and Service

Technical Data

Detailed specifications for NS and DNS series inverters, including DC/AC input/output and efficiencies.

Certifications

Overview of product certifications and approvals across different regions and standards.

Warranty & Service

Information on standard warranty conditions, exceptions, and after-sales service policies.

Goodwe GW5000D-NS Specifications

General IconGeneral
ModelGW5000D-NS
Rated Power5000 W
Max. DC Input Power6500W
Number of MPPT2
Max. Input Current per MPPT13 A
Rated AC Output Power5000 W
Max. AC Apparent Power5500 VA
AC Voltage Range180-280V
Total Harmonic Distortion (THD)<3%
DC SwitchYes
Protection ClassIP65
Protection LevelIP65
Rated Output Voltage230 V
AC Output Voltage230 V
Rated Grid Frequency50 Hz
AC Output Frequency50 Hz
Power Factor>0.99
Operating Temperature Range-25°C to 60°C
Cooling MethodNatural Convection