134
The parameters are set successfully.
Number
Parameter
Description
1
PV Access
Mode
Stand-alone Connect
The PV strings are connected to the MPPT
terminals one by one.
Partial Parallel
Connect
The PV strings are connected to the inverter
in both stand-alone and parallel connection.
For example, one PV string connect to
MPPT1 and MPPT2, another PV string
connect to MPPT3.
Parallel Connect
The external PV string is connected to multi
MPPT terminals of the inverter.
Method II: Setting via LCD
Step 1: Click on the screen or select the settings icon >System Setup>Quick
Setting>PV Connect Mode through the button to enter the settings page.
Step 2: Set up functions according to actual needs.
Number
Parameter
Description
1
PV
Connect
Mode
Stand-alone Connect
The PV strings are connected to the MPPT
terminals one by one.
Partial Parallel
Connect
The PV strings are connected to the inverter
in both stand-alone and parallel connection.