power, the inverter will restart and detect the
power again. The inverter will perform restart and
detection several times until the overloading
problem is solved. Tap Clear Overload History to
reset the restart time interval after the power of
the loads connected to the BACK-UP ports meets
the requirements. The inverter will restart
immediately
9.4.2 Setting Advanced Parameters
9.4.2.1 AFCI
This function supports settings through the SolarGo APP only.
Step 1: Tap Home > Settings > Advanced Settings to set the parameters.
Step 2: Set the parameters based on actual needs. Tap‘√’or Save to save the settings.
The parameters are set successfully.
Number
Parameter
Description
1
AFCI Test
AFCI Test
Enable or disable AFCI accordingly.
AFCI Test Status
The test status, like Not Self-checking, self-
check succeeded, etc.
Clear AFCI Alarm
Clear ARC Faulty alarm records.
Self-check
Tap to check whether the AFCI function
works normally.
9.4.2.2 PV Access Mode
This function supports settings through the SolarGo app or LCD screen.
Method I: Setting via SolarGo APP
Step 1: Tap Home > Settings > Advanced Settings to set the parameters.
Step 2: Set the parameters based on actual needs. Tap‘√’or Save to save the settings.