EasyManuals Logo

Goodwe MT G2 Series User Manual

Goodwe MT G2 Series
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
Moisture parameters
Temperature Range
Humidity Range
3K3
0~+40℃
5%~85%
4K2
-33~+40℃
15%~100%
4K4H
-20~+55℃
4%~100%
Level
Note:
Overvoltage Category Definition
Category I: applies to equipment connected to a circuit where measures have been taken to
reduce transient overvoltage to a low level.
Category II: applies to equipment not permanently connected to the installation. For example,
appliances, portable tools and other plug-connected equipment;
Category III: applies to fixed downstream equipment, including the main distribution board. This
includes switchgear and other equipment in an industrial installation;
Category IV: applies to equipment permanently connected at the origin of an installation
(upstream of the main distribution board).For example, electricity meters, primary
overcurrent protection equipment and other equipment connected directly to
outdoor open lines.
Moisture Location Category Definition
Environment Category Definition
Outdoor: the ambient air temperature is -20-50℃. Relative humidity range is 4-100%, applied to
PD3.
Indoor unconditioned: the ambient air temperature is -20-50℃. Relative humidity range is 5- 95%,
applied to PD3.
Indoor conditioned: the ambient air temperature is 0-40℃. Relative humidity range is 5- 85%,
applied to PD2.
Pollution Degree Definition
Pollution degree 1: No pollution or only dry, non-conductive pollution occurs. The pollution has
no influence.
Pollution degree 2: Normally only non-conductive pollution occurs. However, a temporary
conductivity occasionally caused by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-conductive pollution becomes
conductive because ofcondensation, which is expected.
Pollution degree 4: Persistent conductive pollution occurs. This includes the pollution cause by
conductive dust, rain and snow.
Technical Data
Input
Max. Input Power (W)
Max. Input Voltage (V)
MPPT Operating Voltage Range (V)
Start-up Voltage (V)
Backfeed Current(A)
Nominal Input Voltage (V)
Max. Input Current per MPPT (A)
Max. Short Circuit Current per MPPT (A)
Number of MPPT
Number of Strings per MPPT
Output
Nominal Output Power (W)
Max. AC Active Power (W) [1]
Max. AC Apparent Power (VA)[2]
Nominal Output Voltage (V)
Nominal AC Grid Frequency (Hz)
Max. Output Current (A)
Output Power Factor
Max. Total Harmonic Distortion
Max. Output Fault Current (peak and duration) (A)
Max. Output Overcurrent Protection(A)
Efficiency
Max. Efficiency
European Efficiency
Protection
PV String Current Monitoring
Anti-islanding Protection
DC Insulation Resistance Detection
DC fuse
Anti-PID Function for Module
DC Surge Arrester
AC Surge Arrester
Residual Current Monitoring Unit
AC Overcurrent Protection
AC Short Circuit Protection
AC Overvoltage Protection
General Data
Operating Temperature Range (℃)
Relative Humidity
Max. Operating Altitude (m)
Cooling Method
Display
Communication
Weight (kg)
Dimension (Width * Height * Depth mm)
Ingress Protection Rating
Night Self Consumption (W)
Topology
Certifications & Standards
Grid Regulation
Safety Regulation
EMC Regulation
GW50KBF-MT-KR
65000
1100
200~1000
200
0
620
30
37.5
4
2
50000
55000
55000
400, 3L/N/PE or 3L/PE
50/60
80
180(duration 5us)
180
98.8%
98.3%
GW60KBF-MT-KR
80000
1100
200~1000
200
0
620
30
37.5
4
2
60000
66000
66000
400, 3L/N/PE or 3L/PE
50/60
96
180(duration 5us)
180
98.8%
98.5%
~1 (Adjustable from 0.8 leading to 0.8 lagging)
<3%
Integrated
Integrated
Integrated
Integrated
Optional
Integrated(Type II)
Integrated(Type II)
Integrated
Integrated
Integrated
Integrated
-30~60
0~100%
4000
Smart Fan Cooling
LCD or WiFi+APP
IP65
<1
Transformerless
Visit homepage to achieve information.
RS485 or WiFi or PLC
59kg 64kg
586*788*264
37 38

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe MT G2 Series and is the answer not in the manual?

Goodwe MT G2 Series Specifications

General IconGeneral
BrandGoodwe
ModelMT G2 Series
CategoryInverter
LanguageEnglish