12 Gossen Metrawatt GmbH
Reference Ranges
Line voltage 230 V AC 0.2%
Line frequency 50 Hz 2Hz
waveform
Sine (deviation between effective and rectified value < 0.5%)
Ambient temperature +23 C 2K
Relative humidity 40 60%
Load resistors Linear
Nominal Ranges of Use
Nominal line voltage 100 V 240 V AC
Nominal line frequency
50 Hz 400 Hz
Line voltage waveform
Sinusoidal
Temperature 0 C +40 C
Ambient Conditions
Storage temperature -20 C +60 C
Relative humidity Max. 75%, no condensation allowed
Elevation Max. 2000 m
Place of use Indoors, except within specified ambient
conditions
In order to avoid deviation due to excessive temperature fluctua-
tion, e.g. after outdoor transport at low temperature and subse-
quent operation in a warm indoor environment, it’s advisable to
wait until the test instrument has acclimatized before starting any
measurements.
If the test instrument is colder than the ambient air, condensation
may occur at high humidity, i.e. condensate may accumulate on
components. This could result in the occurrence of parasitic
capacitances and resistances which affect the measuring circuit
and measuring accuracy.
Power Supply
Supply network TN, TT or IT
Line voltage 90 V 264 V AC
Line frequency 50 Hz 400 Hz
Power consumption 200 mA DUT: Approx. 32 VA
10 A DUT: Approx. 105 VA
25 A DUT: Approx. 280 VA
Mains to test socket
(e.g. during function test)
Continuous max. 3600 VA, power is con-
ducted through the instrument only,
switching capacity 16 A, ohmic load, the
AT3-IIS32 (Z745X) adapter (for example)
can be used for current > 16 A AC
Electrical Safety
Protection class I per EN 61140
Nominal voltage 230 V
Test voltage 2.3 kV AC 50 Hz or 3.3 kV DC
(mains circuit / test socket to mains PE ter-
minal, USB, finger contact,
probe(s), test socket)
Measuring category Designed for 300 V CAT II
(but reduced to 250 V CAT II through the
use of fuses for increased user safety. The
user-friendly fuses are replaceable and
replacements are easily obtainable).
Pollution degree 2
Safety shutdown
At DUT differential current of > 10 mA,
shutdown time: < 500 ms,
can also be set to > 30 mA
in the event of probe current (electronic
fuse) during:
–
Leakage current measurement:
> 30 mA~/< 500 ms
*
– Protective conductor resistance
measurement:
>250mA~/<1ms
in case of continuous current I > 16.5 A
Fuse Links Mains fuses: 2 ea. FF 500V/16A
Special fuse: M 250V/250mA
10 A RPE test current (feature G01 only):
1 ea. FF 500V/16A
Electromagnetic Compatibility
Product standard EN 61326-1
EN 61326-2-2
USB Data Port
Type USB slave for PC connection / remote
control**
Type 2 ea. USB master,
for data entry devices * with HID boot
inter
face,
for USB flash drive for data backup,
for USB flash drive for saving reports as
HTML files,
for printers *
* See section 10 for compatible devices
** Remote control only with extension: “Remote Control via PC (IZYTRONIQ)”
(included as standard feature with SECUTEST ST PRO and available with
SECUTEST DB+ (Z853R or feature KB01).
Bluetooth
®
data interface 2.1 + EDR
(test instruments with feature M01 only)
Frequency range Max. 2.5 mW (class II)
Transmission intensity 2400 … 2483.5 MHz
Mechanical Design
Display 4.3" multi-display (9.7× 5.5 cm),
backlit, 480 x 272 pixels
at 24-bit color depth (true color)
Dimensions W × H × D: 295 ×145 × 150 mm
Height with handle: 170 mm
Weight
SECUTEST ST BASE(10)/PRO: approx. 2.5 kg
SECULIFE ST BASE25: approx. 4.0 kg
(depending on the test instrument version)
Protection Housing: IP 40,
Test socket: IP 20
per EN 60529
Table Excerpt Regarding Significance of IP
Codes
SECULIFE ST BASE(25):
Housing with antimicrobial properties per JIS
standard Z 2801
Database
Number of data
records 50,000
1 data record = 1 DUT or location node or
customer or individual measurement
*
Firmware version 3.2.0 and lower: 12 mA
Interference emission Class
EN 55011 B
IEC 61000-3-2 B
IEC 61000-3-3 B
Interference
immunity
Test Value *
Evaluation
Criterion
EN 61000-4-2 Contact/atmos. – 4 kV/8 kV B
EN 61000-4-3 10 V/m (80 MHz … 1 GHz) A
EN 61000-4-4 Mains connection – 2 kV B
EN 61000-4-5 Mains connection – 1 kV (LN), 2 kV (LPE) B
EN 61000-4-6 Mains connection – 3 V A
EN 61000-4-8 30 A/m A
EN 61000-4-11 0%: 1 period B
0%: 250/300 periods C
40%: 10/12 periods C
70%: 25/30 periods C
IP XY
(1
st
digit X)
Protection Against Foreign
Object Ingress
IP XY
(2
nd
digit Y)
Protection Against Water
Ingress
2 12.5 mm 0 Not protected
4 1.0 mm 0 Not protected