Operation
334641E 19
Cleanup
1. Perform Pressure Relief Procedure,
page 9.
2. Remove Tip Guard and Spray Tip. For
additional information, see separate gun
manual.
Fast Flush Drain Tube
3. Remove fluid intake and drain tube from
paint, wipe excess paint off outside.
4. Place fluid intake in flushing fluid. Use
water for water base paint and mineral
spirits for oil-based paint. Place drain
tube in waste pail.
5. To flush drain tube and pump turn prime
valve down.
6. Turn pressure control to Fast Flush
operate until the pump runs steady and
flushing fluid appears in the waste pail.
Fast Flush Hose and Gun
7. To flush airless hose and spray gun, turn
prime valve horizontal.
8. Hold gun against waste pail. Disengage
trigger lock. Trigger gun and turn
pressure control to Fast Flush operate
until the pump runs steady and flushing
fluid appears.
9. Stop triggering gun.
ti24709a
ti24710a