18 3A4476E
5. You can either dispose of the used
FlexLiner and install a new FlexLiner or
clean a used FlexLiner.
6. To clean the sprayer, fill FlexLiner
approximately half-full with appropriate
cleaning fluid (warm water or mineral
spirits).
7. Securely tighten cup support with
FlexLiner to cup cover/sprayer and close
VacuValve.
8. To clean the cup cover and pump filter
shake the entire sprayer for ten seconds.
9. Make certain the Prime Pump/Spray
knob is in the Prime Pump position
(pointed down). Set speed control to 10.
10. Turn the sprayer upside down and point
the sprayer into a waste pail. Pull the
trigger for 15 seconds.