Performance
Charts
50:1
Eagle Grease Pumps Fluid Outlet Pressure
0
1000
2000
3000
4000
5000
6000
7000
8000
0.0 0.4 0.8 1.2 1.6 2.0
(0.18) (0.73)
(14,
140)
(28, 280)
DELIVERY
–– lb/min (kg/min)
(0.91)
(42,
420)
(49, 490)
(56, 560)
Fluid
Pressure Curves
A at
150 psi (0.9 MPa, 10 bar) air pressure
B
at 100 psi (0.7 MPa, 7 bar) air pressure
C
at 70 psi (0.48 MPa, 4.8 bar) air pressure
D
at 40 psi (0.28 MPa, 2.8 bar) air pressure
Test Fluid: No.
2 grease (specific gravity: 0.92)
(35,
350)
(21, 210)
(0.36) (0.54) (1.0)
A
B
C
D
To
find Fluid Outlet Pressure
(psi/MPa/bar) at a
specific delivery rate (lb/min or kg/min) and operating
air pressure (psi/MPa/bar):
1.
Locate delivery rate along bottom of chart.
2.
Follow vertical line up to intersection with selected
fluid outlet pressure curve.
3.
Follow left to scale to read fluid outlet pressure.
FLUID OUTLET PRESSURE –– psi (MPa, bar)
(7,
70)
2.2
Cycles
Per Minute*
21 63
42
84 105 115
*
Recommended pump speed for continuous operation: 95 cpm
Maximum recommended pump speed: 1
15 cpm