EasyManua.ls Logo

Graco EcoQuip 2 EQm - User Manual

Graco EcoQuip 2 EQm
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operation,Repair,andParts
EcoQuip EcoQuip
EcoQuip
2™ 2™
2™
Vapor Vapor
Vapor
Abrasive Abrasive
Abrasive
Blast Blast
Blast
System System
System
3A3489E
EN
Vapor Vapor
Vapor
abrasive abrasive
abrasive
blast blast
blast
system system
system
for for
for
coating coating
coating
removal removal
removal
and and
and
surface surface
surface
preparation. preparation.
preparation.
For For
For
professional professional
professional
use use
use
only. only.
only.
Important Important
Important
Safety Safety
Safety
Instructions Instructions
Instructions
Readallwarningsandinstructionsinthismanual.Savethese
instructions.
175 psi (12.06 bar, 1.2 MPa) Maximum
Working Pressure
See page 3 for Models and approval
information.
PROVENQUALITY.LEADINGTECHNOLOGY.

Other manuals for Graco EcoQuip 2 EQm

Questions and Answers

  • N
    Nicholas HumphreyAug 6, 2025
    How to fix a malfunctioning air regulator on a Graco EcoQuip 2 EQm Water Pump?
    • M
      Marisa MccormickAug 6, 2025
      If the Graco Water Pump air regulator is malfunctioning, first disengage the blast control switch. Then, adjust the pump inlet air pressure regulator until the pump air pressure regulator gauge reads 100 psi. Make sure the supply air pressure is at least 100 psi and check the air inlet filters. If the issue persists, replace the pump air pressure regulator.
  • V
    Victoria PettyAug 10, 2025
    What to do if the pop-up on my Graco EcoQuip 2 EQm cannot seal properly?
    • A
      adamandersonAug 10, 2025
      If your Graco Water Pump pop-up cannot seal, make sure the pop-up is clean and free of any debris, especially in the o-ring sealing area. Check that the pop-up is properly aligned when closed, ensuring there are no gaps between the o-ring and the pop-up. Also, remove the o-ring to make sure the o-ring gland is clear. If the pop-up or o-ring is worn, replace it.
  • S
    smithangelaAug 15, 2025
    What to do if the water pressure regulator is malfunctioning on my Graco EcoQuip 2 EQm Water Pump?
    • J
      Joanna TurnerAug 15, 2025
      If the Graco Water Pump's water pressure regulator is malfunctioning, adjust the water pressure regulator until the pot pressure gauge reads 185 psi (12.75 bar, 1.275 MPa). If this adjustment is not possible, service the water pressure regulator. No answer.
  • S
    scottwoodsAug 19, 2025
    How to disengage the emergency stop on a Graco Water Pump?
    • J
      jennifer17Aug 19, 2025
      To disengage the emergency stop on your Graco Water Pump, simply disengage the emergency stop (L).
  • K
    Kelly ValdezAug 23, 2025
    Why is my Graco Industrial Electrical pot unable to fill or pressurize with water?
    • T
      Thomas GrahamAug 23, 2025
      If you're having trouble filling or pressurizing the Graco Industrial Electrical pot with water, first, disengage the emergency stop. Then, ensure your air compressor meets the minimum air flow requirements specified in the Technical Specifications (page 67) and that the air inlet pressure gauge reads between 100-175 psi. Also, make sure the water tank is full, the inlet ball valve is open, and the water inlet filter is clean. Check the pump air pressure regulator, and adjust it to 100 psi. Finally, ensure the pop-up is clean, properly aligned, and the o-ring sealing area is free of debris. If adjusting the water pressure regulator to 185 psi isn't possible, further service might be needed (see manual 309474).
  • B
    bishopelizabethAug 27, 2025
    What to do if the blast hose recoils heavily on a Graco Industrial Electrical?
    • N
      Nathaniel FowlerAug 27, 2025
      If the blast hose recoils heavily when you engage the blast control switch on your Graco Industrial Electrical system, it could be because the abrasive ball valve was left open during shutdown. To prevent this, follow the shutdown procedure on page 21, step 2. Alternatively, the abrasive ball valve or the pinch hose might be worn. To check, pressurize the pot, close the abrasive ball valve, and engage the blast control switch. If the pump rod is still moving, replace the abrasive ball valve or the pinch hose. For pinch hose replacement, refer to page 32.
  • E
    Eric BrownNov 1, 2025
    What to do if my Graco EcoQuip 2 EQm is unable to fill or pressurize?
    • D
      Daniel AndersonNov 1, 2025
      If your Graco Water Pump pot won't fill or pressurize, first, ensure the emergency stop is disengaged. Then, check that your air compressor meets the system's minimum airflow requirements and that the air inlet pressure gauge reads 100-175 psi. Clean or replace air inlet filters if needed. For inadequate water supply, if you have a water tank, ensure it's full, the inlet ball valve is open, and the water inlet filter is clean. Tighten all fittings. If you have pressurized supply connections, ensure the connection is pressurized, meets pressure and flow needs, and all fittings are tight. Check the inlet water pressure regulator for proper installation and clean its screen filter. If the water pump air regulator is malfunctioning, disengage the blast control switch and adjust the pump inlet ...

Summary

Warnings

General Safety Precautions

General safety warnings for setup, use, grounding, maintenance, and repair.

Hazard Categories

Specific hazards including dust, pressure, misuse, burns, fire, moving parts, and recoil.

Personal Protective Equipment

Essential protective equipment for safe operation.

System Component Identification

Component Overview

Identification of major system components through diagrams.

MediaTrak Controls

Identification and function of MediaTrak controls.

Procedures

Pressure Relief and Grounding

Procedures for pressure relief and grounding ATEX systems.

Operation and Setup

Lifting, hose connection, equipment setup, settings, and application guides.

Maintenance and Shutdown

Procedures for refilling, washing, draining, winterizing, cleaning, and shutdown.

Troubleshooting

Common Operational Issues

Troubleshooting common problems with water supply, pump, and regulators.

Air Flow and Pattern Problems

Diagnosing and fixing issues with blast air flow, abrasive flow, and spray patterns.

System Performance Issues

Addressing dust, fluctuating air, and irregular spray patterns.

Repair

Component Replacement

Procedures for replacing DataTrak battery, fuse, and pinch hose.

Parts and Accessories

Model-Specific Parts

Illustrated and listed parts for various EQ models.

Hoses, Controls, and Other Parts

Details on hoses, controls, accessories, enclosure parts, and common spares.

Vapor Abrasive Blast Systems and Accessories

Blast Hoses and Controls

Specifications for blast hoses with and without control systems.

Nozzles and Compressor Kits

Specifications for nozzles and service kits for compressors.

Other Accessories

List and descriptions of additional accessories available for the systems.

Common Spare Parts

List of commonly used spare parts for the equipment.

Tubing Schematic

Dimensions

Model Dimensions

Dimensional drawings and specifications for various EQ models.

Technical Specifications

EQm Specifications

Technical specifications for the EcoQuip 2 EQm model.

EQs Series Specifications

Technical specifications for EQs, EQs Elite, and EQs2 Elite models.

EQc;EQc Elite;Trailer Specs

Technical specifications for EQc, EQc Elite, EQ200T Elite, and EQ400T Elite models.

Notes

Graco Standard Warranty

Graco EcoQuip 2 EQm Specifications

General IconGeneral
BrandGraco
ModelEcoQuip 2 EQm
CategoryWater Pump
LanguageEnglish

Related product manuals