Operation
8.DisengagetheEmergencyStop.
NOTE: NOTE:
NOTE:
Thewaterpumpwillnotworkunlessthe
EmergencyStopisdisengaged.
9.Alignthepop-uphandlewiththepinslot,and
thenrmlypushandturnthehandle90°afterthe
pinisbelowthebracketslot.Properengagement
ofthepinwillholdthepop-updownuntilitis
released.
10.Add10gallons(30liters)offreshwaterto
thepot.Wearappropriatepersonalprotective
equipment,includinganappropriatelyt-tested
governmentapprovedrespiratorsuitableforthe
dustconditions.Addabrasivematerial(minimum
fourbags,maximumten50lb(23kg)bagsof
high-massabrasive,oreight50lb(23kg)bags
oflowmassabrasive).
1
2
10 gal
(30 L)
200-500 lb
(90-227 kg)
11.Useagardenhoseortherinsehosetowashthe
abrasiveintothepotandclearanyabrasivefrom
thepop-upandgasket.
12.Whenthewaterlevelreachesthepop-upgasket,
rotatethehandletoreleasethepop-uppin.
NOTE: NOTE:
NOTE:
Makesurethepop-upgasketiscleanof
alldebris.
12
334666C