9. Unscrew inlet strainer from suction
tube. Place inlet strainer rinse in waste
pail.
10. Connect garden hose to suction tube
with Power Flush attachment valve.
Leave drain tube in waste pail.
11. Turn ON/OFF switch to ON position.
12. Open Power flush attachment valve.
13. Circulate water through sprayer, into
waste pail, for 20 seconds.
14. Turn ON/OFF switch to OFF position.
NOTE: Step 15 is for returning paint in hose
to paint pail. One 50 ft (15 m) hose holds
approximately 1 quart (1 liter) of paint.
15. To recover paint in hose:
a. Hold gun firmly to the paint pail.
b. Point gun into paint pail.
c. Disengage trigger lock.
d. Pull and hold gun trigger.
e. Place Prime/Spray valve in SPRAY
position.
f. Turn ON/OFF switch to ON position.
g. Continue to hold gun trigger until
you see paint diluted with flushing
fluid starting to come out of gun.
16. While continuing to trigger gun, quickly
move gun to redirect spray into waste
pail. Continue triggering gun into waste
pail until flushing fluid dispensed from
gun is relatively clear.
17. Turn pressure control knob to the
Prime/Clean setting.
18. Stop triggering gun. Engage the trigger
lock.
ti27158a
7
1
55a
t
i
2
7
ti27160a
ti27121a
ti24931a