3A3212C 27
9. Flush until approximately 1/3 of the
flushing fluid is emptied from the hop-
per.
10. Turn ON/OFF switch to OFF position.
NOTE: Step 11 is for returning paint in hose
to paint pail. One 50 ft (15 m) hose holds
approximately 1 quart (1 liter) of paint.
11. To recover paint in hose:
a. Point gun into paint pail.
b. Disengage trigger lock.
c. Pull and hold gun trigger.
d. Place Prime/Spray valve in SPRAY
position.
e. Turn ON/OFF switch to ON position.
f. Continue to hold gun trigger until
you see paint diluted with flushing
fluid starting to come out of gun.
12. While continuing to trigger gun, quickly
move gun to redirect spray into waste
pail. Continue triggering gun into waste
pail until flushing fluid dispensed from
gun is relatively clear.
13. Stop triggering gun. Engage the trigger
lock.
14. Place Prime/Spray valve in PRIME
position.
15. Turn ON/OFF switch to OFF position.
16. On sprayers with a filter, see Cleaning
InstaClean
Fluid Filter, page 28.
17. Fill unit with Pump Armor
storage
fluid. See Storage, page 29.
ti27151a
ti24931a
ti27263a

Related product manuals