Setup
42 3A2797R
20.Install Low Volume Fill Kit (Optional).
a. Perform Pressure Relief Procedure, page 44.
b. Close the ball valves located on the day tanks.
c. Remove the swivel fitting from the day tank inlet
port ball valve.
d. Insert the refill valve onto the ball valve.
e. Install the swivel fitting onto the refill valve
assembly.
f. Remove the air tube fitting installed on the sole-
noid valve located inside the tank stand base
cube.
g. Install the air tube fitting provided with the kit
into the open port on the solenoid valve.
h. Install the air tube from the refill valve to the
solenoid valve.
FIG. 24: Low Volume Refill Kit
r_24m418_3a1961_1a