Technical Data
98 3A2797R
Motor Control Module Technical Data
Motor Control Module
US Metric
Input Specifications:
Input Line Voltage 0-264 Vac, line-to-line
Input Line Phasing Single or Three Phase
Input Line Frequency 50/60 Hz
Input Current per Phase 25A (three-phase), 50A (single-phase)
Maximum Branch Circuit Protection Rating 30A (three-phase), 63A (single-phase)
Short Circuit Current Rating 5 kA
Output Specifications:
Output Line Voltage 0-264 Vac
Output Line Phasing Three Phase
Output Current 0-30A
Output Overload 200% for 0.2 seconds
DC Power Supply 24 Vdc, Class 2, Graco-provided power supply
Enclosure Type 1
Max Ambient Temperature 50°C (122°F)
Overtemperature protection is provided to protect from motor overload.
Current limit, set via the software, is provided as a secondary protection from motor overload.
All installations and wiring must comply with NEC and local electrical codes.